MAUDE Adverse Event Report: FISHER & PAYKEL HEALTHCARE LTD FISHER & PAYKEL HEALTHCARE; RESPIRATORY HUMIDIFIER

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

FISHER & PAYKEL HEALTHCARE LTD FISHER & PAYKEL HEALTHCARE; RESPIRATORY HUMIDIFIER Back to Search Results
Model Number MR850AEU
Medical Device Problem Code Fire (1245)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 10/08/2023
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
(b)(4).The complaint mr850 respiratory humidifier and accessories have been requested to be returned to fisher & paykel healthcare (f&p) for evaluation.We will provide a follow up report upon completion of investigation.
 
Event or Problem Description
A distributor in india reported, via a fisher & paykel (f&p) healthcare field representative, an incident in which a fire occurred when setting up a bubble cpap system.An mr850 respiratory humidifier was part of the set-up and was being used with a f&p healthcare temperature probe and a non f&p healthcare heaterwire adaptor (manufacturer unknown).The user facility reported to f&p healthcare that the bubble cpap system was set up and connected to oxygen at 5l/min in preparation for patient use.Within approximately 10 minutes of initial set-up the device was observed to be on fire.It was also reported that the bc161 bubble cpap system had been in patient use for approximately one year.There was no patient involvement or injuries reported as a result of this event.The complaint device and accessories have been requested to be returned to f&p healthcare for further analysis.
 
Event or Problem Description
A distributor in india reported, via a fisher & paykel (f&p) healthcare field representative, an incident in which a fire occurred when setting up a bubble cpap system.The healthcare facility reported to f&p healthcare that the bubble cpap system was being set up in preparation for patient use however the devices were not in use on a patient nor connected to a patient at the time of the reported event.The system included an f&p healthcare mr850 respiratory humidifier that was being used with a f&p healthcare temperature probe and a non-f&p healthcare heaterwire adaptor (manufacturer unknown).The healthcare facility also reported that the f&p healthcare bc161 bubble cpap system had been re-used for approximately one year and had been used on multiple patients during this time.The healthcare facility reported that, following set up of the devices and prior to patient use, the mr850 respiratory humidifier was powered on and heating, and the oxygen was connected with a flow rate of 5l/min.Within approximately 10 minutes the humidification chamber, which is provided as part of the bc161 bubble cpap system, was observed to be on fire.There was no patient involvement or user injuries reported as a result of this event.
 
Additional Manufacturer Narrative
(b)(4).Method: the subject mr850 respiratory humidifier and associated devices were requested for evaluation however no products were returned to fisher & paykel healthcare for analysis.Our investigation is therefore based on the information, photographs and video provided by the healthcare facility, and our knowledge of the product.Results: the healthcare facility reported that a fire occurred when setting up a bubble cpap system.The devices were not in use on a patient nor connected to a patient at the time of the reported event.The healthcare facility reported that, following set up of the devices, the mr850 respiratory humidifier was powered on and heating, and the oxygen was connected with a flow rate of 5l/min.Within approximately 10 minutes the humidification chamber, which is provided as part of the cb161 bubble cpap system, was observed to be on fire.The healthcare facility also reported that the f&p healthcare bc161 bubble cpap system had been re-used for approximately one year and had been used on multiple patients during this time.Review of the video file provided by the healthcare facility confirmed that the devices were not connected to a patient when the fire occurred.The video file shows the humidification chamber fitted to the mr850 respiratory humidifier is on fire.The hospital staff are seen extinguishing the fire.There are multiple electrical cables visible on the floor in the location of the bubble cpap system devices.Other medical devices, including an infant warmer and a syringe pump, are also visible in close proximity.The photographs provided confirm that the heaterwire adaptor in use at the time of the reported event was not manufactured by f&p healthcare.The heaterwire adaptor provides electrical power from the respiratory humidifier to the inspiratory and expiratory circuit limbs.Review of the photographs and the video showed evidence of fire damage to the re-used humidification chamber dome (melted), temperature probe, non-f&p healthcare heater wire adaptor and part of the inspiratory circuit.Conclusion: without the return of the subject device, we are unable to determine what may have caused the reported fire.The healthcare facility confirmed that a non-approved heaterwire adaptor was being used at the time of the fire.Additionally, the healthcare facility reported that the single-use bc161 bubble cpap system (including the heated wire breathing circuits) had been in use for approximately one year and used on multiple patients during this time.The user instructions for the mr850 state the following: "the use of breathing circuits, chambers or other accessories which are not approved by fisher & paykel healthcare may impair performance and compromise safety." "remove any sources of ignition, such as cigarettes, an open flame, or materials which burn or ignite easily at high oxygen concentrations." the user instructions for the bc161 state the following: "all components of the bubble cpap system are single use only." "do not reuse any part of the bc161.It is manufactured for single patient use only.Reuse may result in transmission of infectious substances, interruption to treatment, serious harm or death." "this product is intended to be used for a maximum of 7 days." "remove any sources of ignition, such as cigarettes or open flames." "do not add or modify any attachments or accessories to the humidifier that are not specified or approved for use with the humidifier or accessory, or the humidifier might not function correctly, affecting the quality of the therapy or injuring the patient." "the responsible organization is accountable for the compatibility of the humidifier and all of the parts and accessories used to connect to the patient and other equipment before use." "do not soak, wash, sterilize or reuse this product.Avoid contact with non-approved chemicals".
 
Event or Problem Description
A distributor in india reported, via a fisher & paykel (f&p) healthcare field representative, an incident in which a fire occurred when setting up a bubble cpap system.The healthcare facility reported to f&p healthcare that the bubble cpap system was being set up in preparation for patient use however the devices were not in use on a patient nor connected to a patient at the time of the reported event.The system included an f&p healthcare mr850 respiratory humidifier that was being used with a f&p healthcare temperature probe and a non-f&p healthcare heaterwire adaptor (manufacturer unknown).The healthcare facility also reported that the f&p healthcare bc161 bubble cpap system had been re-used for approximately one year and had been used on multiple patients during this time.The healthcare facility reported that, following set up of the devices and prior to patient use, the mr850 respiratory humidifier was powered on and heating, and the oxygen was connected with a flow rate of 5l/min.Within approximately 10 minutes the humidification chamber, which is provided as part of the bc161 bubble cpap system, was observed to be on fire.There was no patient involvement or user injuries reported as a result of this event.
 
Additional Manufacturer Narrative
(b)(4).**udi related data quality updates only** corrections to reflect gudid: section d1: brand name updated to fisher & paykel healthcare.Section d2a: common device name updated to respiratory humidifier.Section d4: model and catalog # updated to mr850aeu.Section g1: contact person updated to mr.(b)(4).Method: the subject mr850 respiratory humidifier and associated devices were requested for evaluation however no products were returned to fisher & paykel healthcare for analysis.Our investigation is therefore based on the information, photographs and video provided by the healthcare facility, and our knowledge of the product.Results: the healthcare facility reported that a fire occurred when setting up a bubble cpap system.The devices were not in use on a patient nor connected to a patient at the time of the reported event.The healthcare facility reported that, following set up of the devices, the mr850 respiratory humidifier was powered on and heating, and the oxygen was connected with a flow rate of 5l/min.Within approximately 10 minutes the humidification chamber, which is provided as part of the cb161 bubble cpap system, was observed to be on fire.The healthcare facility also reported that the f&p healthcare bc161 bubble cpap system had been re-used for approximately one year and had been used on multiple patients during this time.Review of the video file provided by the healthcare facility confirmed that the devices were not connected to a patient when the fire occurred.The video file shows the humidification chamber fitted to the mr850 respiratory humidifier is on fire.The hospital staff are seen extinguishing the fire.There are multiple electrical cables visible on the floor in the location of the bubble cpap system devices.Other medical devices, including an infant warmer and a syringe pump, are also visible in close proximity.The photographs provided confirm that the heaterwire adaptor in use at the time of the reported event was not manufactured by f&p healthcare.The heaterwire adaptor provides electrical power from the respiratory humidifier to the inspiratory and expiratory circuit limbs.Review of the photographs and the video showed evidence of fire damage to the re-used humidification chamber dome (melted), temperature probe, non-f&p healthcare heater wire adaptor and part of the inspiratory circuit.Conclusion: without the return of the subject device, we are unable to determine what may have caused the reported fire.The healthcare facility confirmed that a non-approved heaterwire adaptor was being used at the time of the fire.Additionally, the healthcare facility reported that the single-use bc161 bubble cpap system (including the heated wire breathing circuits) had been in use for approximately one year and used on multiple patients during this time.The user instructions for the mr850 state the following: "the use of breathing circuits, chambers or other accessories which are not approved by fisher & paykel healthcare may impair performance and compromise safety." "remove any sources of ignition, such as cigarettes, an open flame, or materials which burn or ignite easily at high oxygen concentrations." the user instructions for the bc161 state the following: "all components of the bubble cpap system are single use only." "do not reuse any part of the bc161.It is manufactured for single patient use only.Reuse may result in transmission of infectious substances, interruption to treatment, serious harm or death." "this product is intended to be used for a maximum of 7 days." "remove any sources of ignition, such as cigarettes or open flames." "do not add or modify any attachments or accessories to the humidifier that are not specified or approved for use with the humidifier or accessory, or the humidifier might not function correctly, affecting the quality of the therapy or injuring the patient." "the responsible organization is accountable for the compatibility of the humidifier and all of the parts and accessories used to connect to the patient and other equipment before use." "do not soak, wash, sterilize or reuse this product.Avoid contact with non-approved chemicals.".
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
FISHER & PAYKEL HEALTHCARE
Common Device Name
RESPIRATORY HUMIDIFIER
Manufacturer (Section D)
FISHER & PAYKEL HEALTHCARE LTD
15 maurice paykel place
east tamaki
auckland, 2013
NZ  2013
Manufacturer (Section G)
FISHER & PAYKEL HEALTHCARE LTD
15 maurice paykel place
east tamaki
auckland, 2013
NZ   2013
Manufacturer Contact
diego vargas banuelos
17400 laguna canyon road
suite 300
irvine, CA 92618
9494341005
MDR Report Key18089290
Report Number9611451-2023-00962
Device Sequence Number17823860
Product Code BTT
UDI-Device Identifier09420012407207
UDI-Public(01)09420012407207(10)2101581704(11)210331
Combination Product (Y/N)N
Initial Reporter CountryIN
PMA/510(K) Number
K110019
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Foreign,Company Representative,Distributor
Initial Reporter Occupation Other
Type of Report Initial,Followup,Followup
Report Date (Section B) 10/09/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberMR850AEU
Device Catalogue NumberMR850AEU
Device Lot Number2101581704
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 10/09/2023
Supplement Date Received by Manufacturer10/09/2023
10/09/2023
Initial Report FDA Received Date11/07/2023
Supplement Report FDA Received Date03/28/2024
09/08/2024
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured03/31/2021
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Reuse
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
BIOMED BLENDER; BIOMED BLENDER; BIOMED BLENDER; F&P BC161 BUBBLE CPAP SYSTEM; F&P BC161 BUBBLE CPAP SYSTEM; F&P BC161 BUBBLE CPAP SYSTEM; F&P BC191 FLEXITRUNK NASAL CPAP INTERFACE; F&P BC191 FLEXITRUNK NASAL CPAP INTERFACE; F&P BC191 FLEXITRUNK NASAL CPAP INTERFACE; F&P TEMPARATURE PROBE; F&P TEMPARATURE PROBE; F&P TEMPARATURE PROBE; NON-F&P HEATERWIRE ADAPTER; NON-F&P HEATERWIRE ADAPTER; NON-F&P HEATERWIRE ADAPTER
Patient SexUnknown
-
-