A sentrant sheath was used as a conduit during the treatment of a dissection flap that extended from both iliacs to the lsa.The patient had initially undergone a pci resulting in a dissected rca, followed by cabg with an av valve.While on ecmo, the patient had a cold, pale, and paralyzed foot.Prior to the placement of a thoracic stent to address the dissection flap extending from both iliacs to the lsa, the patients leg was amputated.It was reported during the procedure to implant the stent in the descending aorta the sentrant sheath was in the right common iliac.After the stent was deployed and the delivery system was removed the physician was unable to move the sheath proximal or distal.Ni troglycerin was given.The sheath was removed with the blood pressure rapidly decreasing.A rupture of the right common iliac occurred after the sheath was removed.Several covered stents were placed to cover the rupture but a leak still remained.Compressions were given and the patient was sent to the floor.It was reported the patient later expired.The cause of the rupture was determined to be anatomy related where it was noted that the artery was fragile leading to the rupture.The cause of death was due to the iliac rupture.
|
|
Medtronic is submitting this report to comply with fda reporting regulations under 21 cfr parts 4 and 803.This report is based upon information obtained by medtronic, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Medtronic has made reasonable efforts to obtain more complete information and has provided as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any ¿defects¿ or has ¿malfunctioned¿.These words are included in the fda 3500a form and are fixed items for selection created by the fda to categorize the type of event solely for the purpose of regulatory reporting.Medtronic objects to the use of these words and others like them because of the lack of definition and the connotations implied by these terms.This statement should be included with any information or report disclosed to the public under the freedom of information act.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
|