Catalog Number 48930005
Medical Device Problem Codes Fracture (1260); Mechanical Jam (2983)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 10/16/2023
Type of Reportable Event Malfunction
Event or Problem Description
A company representative reported that during insertion, the tritanium tl steerable inserter inner shaft would not release the tritanium tl cage.The procedure was completed successfully using a replacement device with no surgical delay and no adverse consequence to the patient.This report captures the tritanium tl steerable inserter inner shaft.
 
Event or Problem Description
A company representative reported that during insertion, the tritanium tl steerable inserter inner shaft would not release the tritanium tl cage.The procedure was completed successfully using a replacement device with no surgical delay and no adverse consequence to the patient.This report captures the tritanium tl steerable inserter inner shaft.
 
Additional Manufacturer Narrative
H6 coding has been updated to reflect completion of the investigation.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
STEERABLE INSERTER SHAFT
Common Device Name
ORTHOPEDIC MANUAL SURGICAL INSTRUMENT
Manufacturer (Section D)
STRYKER SPINE-US
2 pearl court
allendale NJ 07401
Manufacturer (Section G)
STRYKER SPINE-FRANCE
zone industrielle de marticot
cestas 33610
FR   33610
Manufacturer Contact
rita karan
2 pearl court
allendale, NJ 07401
2017608000
MDR Report Key18145342
Report Number0009617544-2023-00072
Device Sequence Number7502864
Product Code LXH
UDI-Device Identifier07613327370133
UDI-Public07613327370133
Combination Product (Y/N)N
Initial Reporter StatePA
Initial Reporter CountryUS
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Company Representative
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 02/16/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Catalogue Number48930005
Device Lot Number17C628
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer11/02/2023
Is the Reporter a Health Professional? No
Type of Report(Section G)Follow-Up
Initial Date Received by Manufacturer 10/16/2023
Supplement Date Received by Manufacturer01/19/2024
Initial Report FDA Received Date11/15/2023
Supplement Report FDA Received Date02/16/2024
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured05/28/2018
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Reuse
Patient Sequence Number1