• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: ORTHO-CLINICAL DIAGNOSTICS, INC. VITROS CHEMISTRY PRODUCTS AMON SLIDES; IN-VITRO DIAGNOSTICS

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ORTHO-CLINICAL DIAGNOSTICS, INC. VITROS CHEMISTRY PRODUCTS AMON SLIDES; IN-VITRO DIAGNOSTICS Back to Search Results
Catalog Number 1726926
Medical Device Problem Code High Test Results (2457)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 10/30/2023
Type of Reportable Event Malfunction
Event or Problem Description
A customer contacted the (b)(6) center (tsc) to report higher than expected vitros ammonia (amon) results were obtained when processing mas alcohol/ammonia control level 2, lot aa24011 on a vitros 5600 and vitros xt7600 system.Vitros 5600 system (s/n (b)(6)) mas alcohol/ammonia control level 2, lot aa24012 vitros amon results 238.1, 239.2, 231.7, 213.7 and 210.1 umol/l versus baseline mean 167.0 umol/l vitros xt7600 system (s/n (b)((6)) mas alcohol/ammonia control level 2, lot aa24012 vitros amon result 209.5 umol/l versus baseline mean 167.0 umol/l biased results of the magnitude and direction observed may lead to inappropriate physician action if they were to occur undetected on patient samples.The higher than expected vitros amon results were obtained when processing quality control fluids.There was no report of affected patient samples.There was no allegation of patient harm as a result of this event.This report is number one of six mdr¿s for this event.Six 3500a forms are being submitted for this event as six devices were involved.This report corresponds to ortho clinical diagnostics inc (ortho) complaint numbers (b)(4) and reportability assessment 603952.
 
Additional Manufacturer Narrative
The investigation concludes that higher than expected vitros ammonia (amon) results were obtained when processing mas alcohol/ammonia control level 2, lot aa24011 on a vitros 5600 and vitros xt7600 system.The definitive assignable cause of the event is unknown.An unknown quality control fluid handling issue could not be ruled out as the cause of the higher-than-expected vitros amon results.Historical vitros amon quality control results verify the performance of vitros amon slide lot 1019-0263-9013 in combination with both the vitros 5600 and the vitros xt76cfg1`00 systems leading up to the event.Additionally, acceptable vitros amon results were obtained with the same calibration curve and the same vitros amon slide cartridge.However, the customer did not process within-run precision testing on either analyzer, and did not process any vitros liquid performance verifier fluids; therefore, an issue with the vitros 5600 and vitros xt7600 systems and the vitros amon assay could not be fully ruled out as contributors to the event.Continual tracking and trending does not indicate a systemic issue with vitros amon lot 1019-0263-9013.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
VITROS CHEMISTRY PRODUCTS AMON SLIDES
Common Device Name
IN-VITRO DIAGNOSTICS
Manufacturer (Section D)
ORTHO-CLINICAL DIAGNOSTICS, INC.
100 indigo creek drive
rochester NY 14626
Manufacturer (Section G)
ORTHO-CLINICAL DIAGNOSTICS, INC.
513 technology boulevard
rochester NY 14626
Manufacturer Contact
laurie o'riordan
microtyping systems
1295 southwest 29th avenue
pompano beach, FL 33069
9549709500
MDR Report Key18220851
Report Number0001319809-2023-00172
Device Sequence Number14870795
Product Code JID
UDI-Device Identifier10758750000012
UDI-Public10758750000012
Combination Product (Y/N)N
Initial Reporter StateAZ
Initial Reporter CountryUS
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date (Section B) 11/28/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date09/01/2024
Device Catalogue Number1726926
Device Lot Number1019-0263-9013
Was Device Available for Evaluation? Yes
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 10/31/2023
Initial Report FDA Received Date11/28/2023
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured03/02/2023
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Patient SexUnknown
-
-