|
Patient medication was provided: hypertension, pvd, renal disease, arrhythmia, atrial fibrillation; neuropathy; gastroesophageal reflux disease; high cholesterol; arthritis.H6: code c21 - results pending completion of product history review.H6: code c20 - the device remains implanted and, therefore, was not available for direct analysis by gore.It should be noted that, per the gore® excluder® aaa endoprosthesis instructions for use (ifu), adverse events that may occur and / or require intervention include, but are not limited to, endoleak and aneurysm enlargement.W.L.Gore & associates, inc.(gore) is submitting this report to comply with 21 c.F.R.Part 803, the medical device reporting regulation.This report is based upon information obtained by gore, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Blank fields present on this report include required fields and fields determined to be not applicable.Blank required fields indicate that the information was not provided, was deemed unavailable or was not applicable.This report does not constitute an admission or a conclusion by fda, gore, or its associates that the device, gore or its associates caused or contributed to the event described in the report.In particular, this report does not constitute a legal admission by anyone that the product described in this report has any defects or has malfunctioned, as defined from a legal standpoint.These words are included in the report and are fixed items for selection created by the fda, to categorize the type of event solely for the purpose of reporting pursuant to part 803.This statement should be included with any information or report disclosed to the public under the freedom of information act.
|
|
The following information was reported to gore: on (b)(6) 2020, patient underwent an endovascular procedure for treatment of abdominal aortic aneurysm utilizing gore® excluder® aaa endoprosthesis (rlt351414 and plc201000).On (b)(6) 2022, patient underwent reintervention surgery due to aneurysm enlargement noted on plc201000 side (amount unknown), attributed to disease progression.No endoleak was noted.Physician extended distally.A gore® excluder® aaa endoprosthesis contralateral component was implanted.On (b)(6) 2023 patient underwent reintervention surgery due to aneurysm enlargement (less than 0.5cm) on the right side ((rlt351414), attributed to disease progression.No endoleak was observed.The physician decided to place a limb extension using a contralateral leg to extend the seal zone several centimeters all the way to the origin of the right hypogastric artery.This extension was completed using the following device: plc201000 l/s#: (b)(6).Patient tolerated the procedure.
|