Medtronic is submitting this report to comply with fda reporting regulations under 21 cfr parts 4 and 803.This report is based upon information obtained by medtronic, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Medtronic has made reasonable efforts to obtain more complete information and has provided as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any ¿defects¿ or has ¿malfunctioned¿.These words are included in the fda 3500a form and are fixed items for selection created by the fda to categorize the type of event solely for the purpose of regulatory reporting.Medtronic objects to the use of these words and others like them because of the lack of definition and the connotations implied by these terms.This statement should be included with any information or report disclosed to the public under the freedom of information act.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
|
|
Medtronic received information that during use of a bio-medicus life support cannula, the customer reported that there was a small crack identified in the coupling piece and they suspected there was a crack at the top of the connector.The customer stated there was no leak and the patient was not harmed.The crack was discovered a day after admission and appeared like a small white line.The duration of the treatment with the defective device was three days.The customer stated there was no problem inserting this cannula.There was no harm or blood loss related to the cannula.The device was used to complete the procedure as there was no leak observed.There was no adverse patient effect associated with this event, however the patient is now deceased and the customer stated that it was not in any way related to the cannula.Medtronic received additional information that the cannula was not heated or cooled prior to use.The damage was not in the location of the sutures.The cannula was being used for an extra corporeal membrane oxygenation (ecmo) procedure.
|