MAUDE Adverse Event Report: MAQUET SAS VOLISTA STANDOP; LAMP, SURGICAL

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

MAQUET SAS VOLISTA STANDOP; LAMP, SURGICAL Back to Search Results
Model Number ARDSAT209010A
Medical Device Problem Codes Corroded (1131); Peeled/Delaminated (1454)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Event site telephone: (b)(6).Additional information will be provided following the conclusion of the investigation.H3 other text : device not returned to manufacturer.
 
Event or Problem Description
On (b)(6) 2023 getinge became aware of an issue with one of surgical lights - satelite volsita standop.During the preventive maintenance the paint chip and corrosion issues were detected on the satellite tube and fork.Based on photographic evidence the paint chipping and rust occurred on fork and spring arm and ceiling covers.There was no injury reported, however, we decided to report the issue in abundance of caution as any particles falling off into sterile field or during procedure may cause contamination in case of reoccurrence.
 
Additional Manufacturer Narrative
The correction of b5 describe event and problem deems required.This is based on the internal evaluation.Previous b5 describe event and problem: on 9th november, 2023 getinge became aware of an issue with one of surgical lights - satelite volsita standop.During the preventive maintenance the paint chip and corrosion issues were detected on the satellite tube and fork.Based on photographic evidence the paint chipping and rust occurred on fork and spring arm and ceiling covers.There was no injury reported, however, we decided to report the issue in abundance of caution as any particles falling off into sterile field or during procedure may cause contamination in case of reoccurrence.Corrected b5 describe event and problem: on 9th november, 2023 getinge became aware of an issue with one of surgical lights - satelite volista standop.During the preventive maintenance the paint chip and corrosion issues were detected on the satellite tube.Based on photographic evidence the paint chipping and rust occurred on spring arm and ceiling covers.There was no injury reported, however, we decided to report the issue in abundance of caution as any particles falling off into sterile field or during procedure may cause contamination in case of reoccurrence.Initial reporter was getinge technician getinge became aware of an issue with one of surgical lights - satelite volista standop.During the preventive maintenance the paint chip and corrosion issues were detected on the satellite tube.Based on photographic evidence the paint chipping and rust occurred on spring arm and ceiling covers.There was no injury reported, however, we decided to report the issue in abundance of caution as any particles falling off into sterile field or during procedure may cause contamination in case of reoccurrence.According to information provided by the technician the issue probably occurred due to fumigation performed by a customer on the device.Based on the information collected, it was established that when the event occurred, the surgical light did not meet its specification due to rust occurrence and paint peeling.Such a scenario could be considered as technical deficiency, and in this way the device contributed to the event.When reviewing reportable events for this type of issues we were able to establish that the received incidents are occurring at a low (for the rust issue) and moderate (for the paint peeling issue) ratio.We have been able to confirm that the investigated issues have never led to serious injury or worse, to our knowledge.Provided information indicates that upon the event occurrence the device was not being used for patient treatment.As stated by the subject matter expert at manufacturing site, the photographic evidence shows rust formation and paint peeling on the device.It can be observed that the degradation of the paint and corrosion are mostly localized on the retention areas which shows that the stagnation of liquid or cleaning agent residues have caused paint damages and appearance of rust.Peeling paint and rust formation were probably caused by: - a stagnation of aggressive disinfectant and detergent products due to an inappropriate cleaning protocol.- the presence of liquid water or an exposure to humid air due to a high relative humidity of the operating room.The instruction for use indicates the environmental condition for use, the relative humidity must be between 20% and 75% (ifu 01781 en 19, page 29).To prevent any incident the instruction for use mentions to perform daily and monthly inspection in order to detect painting defects, impact marks or other damages (ifu 01781 en 19, page 37).The instruction for use mentions not to clean the device under running water nor spray a solution directly onto the device.Certain cleaning products or procedures may damage the paintwork of the device, which may result in particles falling onto the surgical site during an operation.Fumigation methods are unsuitable for disinfecting the unit and must not be used (ifu 01781 en 19, page 89).The instruction for use mentions to wipe with a dry cloth and to make sure no liquid residue is left on the device after cleaning (ifu 01781 en 19, page 90).To reduce the appearance of rust or the degradation of the surface, the technical manual or maintenance manual mentions in the preventive maintenance protocol to lubricate some parts of device.The instruction for use mentions not to use a damaged device because it may lead to a risk of injury for users or a risk of infection for patients (nm 01780 en 03 extract).Getinge shall continue to monitor for any further events of this nature and do not propose any further action at this time.
 
Event or Problem Description
On 9th november, 2023 getinge became aware of an issue with one of surgical lights - satelite volista standop.During the preventive maintenance the paint chip and corrosion issues were detected on the satellite tube.Based on photographic evidence the paint chipping and rust occurred on spring arm and ceiling covers.There was no injury reported, however, we decided to report the issue in abundance of caution as any particles falling off into sterile field or during procedure may cause contamination in case of reoccurrence.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
VOLISTA STANDOP
Common Device Name
LAMP, SURGICAL
Manufacturer (Section D)
MAQUET SAS
parc de limere
avenue de la pomme de pin
ardon
Manufacturer (Section G)
MAQUET SAS
parc de limere
avenue de la pomme de pin
ardon
Manufacturer Contact
pascal jay
parc de limere
avenue de la pomme de pin
ardon 
MDR Report Key18264845
Report Number9710055-2023-00934
Device Sequence Number12685565
Product Code FTD
UDI-Device Identifier03700712405410
UDI-Public(01)03700712405410
Combination Product (Y/N)N
Initial Reporter CountryIN
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,User Facility,Company Representative
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 12/05/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Other
Device Model NumberARDSAT209010A
Device Catalogue NumberARDSAT209010A
Was Device Available for Evaluation? Yes
Is the Reporter a Health Professional? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 11/09/2023
Supplement Date Received by Manufacturer04/08/2024
Initial Report FDA Received Date12/05/2023
Supplement Report FDA Received Date04/16/2024
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured06/11/2018
Is the Device Labeled for Single Use? (Y/N) No
Usage of Device Reuse
Patient Sequence Number1
Patient SexUnknown
-
-