Model Number 545-513
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Codes Great Vessel Perforation (2152); Cardiac Perforation (2513)
Date of Event 11/10/2023
Type of Reportable Event Serious Injury
Event or Problem Description
A lead extraction procedure commenced to remove a right atrial (ra), a right ventricular (rv), and a left ventricular (lv) lead due to infection.Spectranetics lead locking devices (llds) were inserted into each lead to provide traction.The ra and lv leads were removed successfully without any issues.Then, using a spectranetics 14f glidelight laser sheath to remove the rv lead, the helix of the lead did not come back after use of lasing and traction.Devices switched to a spectranetics 13f tightrail rotating dilator sheath; and although progress was being made, the lead had not completely freed when the patient''s blood pressure dropped.Rescue efforts began immediately, including bypass and sternotomy.A perforation of the inferior vena cava (ivc)/ra junction was discovered and repaired.The rv lead was removed completely post-sternotomy, and the patient survived the procedure.This report captures the 13f tightrail in use when the perforation occurred, requiring intervention.There was no alleged malfunction of any spectranetics devices in use during the procedure.
 
Additional Manufacturer Narrative
D4): device lot, expiration date unk.Partial udi populated.H3): the device was discarded, thus no investigation could be completed.H4): device manufacture date unk because lot number unk.H6): great vessel perforation and cardiac perforation are known risks of complication with use of the tightrail device.Submission of this report does not, in itself, represent a conclusion by the manufacturer and/or authorized representative or the national competent authority that the content of this report is complete or accurate, that the medical device(s) listed failed in any manner and/or that the medical device(s) caused or contributed to an alleged death or deterioration in the state of the health of any person.
 
Additional Manufacturer Narrative
Udi related data quality updates only: d4): correction: removing primary di number from udi# field.The lot number was not provided, thus an entire udi# is unavailable.G3): on 11jul2024, the manufacturer received fda email correspondence identifying a discrepancy in the udi information (section d of the initial mdr).Submission of this report does not, in itself, represent a conclusion by the manufacturer and/or authorized representative or the national competent authority that the content of this report is complete or accurate, that the medical device(s) listed failed in any manner and/or that the medical device(s) caused or contributed to an alleged death or deterioration in the state of the health of any person.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
TIGHTRAIL ROTATING DILATOR SHEATH
Common Device Name
DILATOR, VESSEL, FOR PERCUTANEOUS CATHETERIZATION
Manufacturer (Section D)
SPECTRANETICS CORPORATION
9965 federal drive
colorado springs CO 80921
Manufacturer (Section G)
SPECTRANETICS CORPORATION
9965 federal drive
colorado springs CO 80921
Manufacturer Contact
barbara creel
9965 federal drive
colorado springs, CO 80921
719447-2465
MDR Report Key18271314
Report Number3007284006-2023-00085
Device Sequence Number14425730
Product Code DRE
UDI-Device Identifier00813132020897
UDI-Public00813132020897
Combination Product (Y/N)N
Initial Reporter StateMA
Initial Reporter CountryUS
PMA/510(K) Number
K150360
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 07/22/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Model Number545-513
Device Catalogue Number545-513
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer Not provided
Supplement Date Received by Manufacturer07/11/2024
Initial Report FDA Received Date12/05/2023
Supplement Report FDA Received Date07/22/2024
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
SPECTRANETICS 14F GLIDELIGHT LASER SHEATH; SPECTRANETICS CVX-300 EXCIMER LASER SYSTEM; SPECTRANETICS LEAD LOCKING DEVICES; ST. JUDE MEDICAL 1458 LV LEAD; ST. JUDE MEDICAL 1688 RA PACING LEAD; ST. JUDE MEDICAL 7121 RV ICD LEAD
Outcome Attributed to Adverse Event Required Intervention; Life Threatening;
Patient Age43 YR
Patient SexMale
Patient Weight108 KG
Patient EthnicityNon Hispanic
Patient RaceWhite
-
-