ABBOTT MEDICAL AMPLATZER SEPTAL OCCLUDER; TRANSCATHETER SEPTAL OCCLUDER Back to Search Results
Catalog Number 9-ASD-007
Medical Device Problem Code Difficult to Fold, Unfold or Collapse (1254)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 11/13/2023
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that a 7mm amplatzer septal occluder was selected for implant on (b)(6) 2023 using an 8f amplatzer talisman delivery system.During implant the left disc of the device took on a cobra shape.The device was removed from the patient and replaced with a new 8mm amplatzer septal occluder.During implant, the left disc of the device also took on a cobra shape.The device was removed from the patient and replaced with a new 9mm amplatzer septal occluder, which was implanted successfully.There were no interactions with cardiac structures, nor were there any angulations nor kinks noted in the delivery system.The patient remained hemodynamically stable throughout the procedure.There were no adverse effects to the patient.The patient status is noted as stable.
 
Additional Manufacturer Narrative
Investigation is not yet complete.A follow-up report will be submitted with all additional relevant information.
 
Additional Manufacturer Narrative
An event of device deformity was reported.A returned device assessment could not be performed as the device was not returned for analysis.However, two photos were received from the field appearing to show the devices presenting deformation.The device history record was reviewed to ensure that each manufacturing and inspection operation was performed, and the product met all defined manufacturing specifications.Based on the information received, the cause of the reported incident could not be conclusively determined but could have been as a result of the use of a larger than recommended delivery system as the use of a larger sheath may influence deformations.There is no indication of a product quality issue with respect to labeling design or manufacturing of the device.Please note that the recommended size delivery system per the instructions for use is a 6fna.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
AMPLATZER SEPTAL OCCLUDER
Common Device Name
TRANSCATHETER SEPTAL OCCLUDER
Manufacturer (Section D)
ABBOTT MEDICAL
5050 nathan lane n
plymouth MN 55442
Manufacturer (Section G)
ST. JUDE MEDICAL #3014918977
edificio #44 calle 0, ave. 2
el coyol alajuela 1897- 4050
CS   1897-4050
Manufacturer Contact
karen krouse
5050 nathan lane n
plymouth, MN 55442
6517565400
MDR Report Key18277338
Report Number2135147-2023-05343
Device Sequence Number6263759
Product Code MLV
UDI-Device Identifier00811806010045
UDI-Public00811806010045
Combination Product (Y/N)N
Initial Reporter CountryGM
PMA/510(K) Number
P000039
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2023
Device Explanted Year2023
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 01/02/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Catalogue Number9-ASD-007
Device Lot Number8537898
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 11/13/2023
Supplement Date Received by Manufacturer12/08/2023
Initial Report FDA Received Date12/06/2023
Supplement Report FDA Received Date01/02/2024
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured06/24/2022
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
AMPLATZER TALISMAN DELIVERY SYSTEM, 9-TDS08F45-80
Patient SexUnknown
-
-