Model Number XTACK-160-H
Medical Device Problem Codes Separation Problem (4043); Premature Separation (4045)
Health Effect - Clinical Code Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available (4581)
Date of Event 06/27/2022
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Combined medwatch submitted to the fda on 07/dec/2023.Clinical study: 01 - 016.A review of the device labeling notes the following: the current x-tack¿ endoscopic helix tacking system instructions for use (ifu) addressed the known and potential events of premature separation of tack as follows: the x-tack¿ system is intended for approximation of soft tissue in minimally invasive gastroenterology procedures (e.G.Closure and healing of esd/emr sites, and closing of fistula, perforation or leaks).Precautions the system may only be used if purchased from apollo endosurgery, inc.Or one of its authorized agents.Advance device catheter and push helix tack against tissue.Caution: ensure the handle is in reset.Position prior to driving helix tack.Note: do not retract device catheter from.The working channel whilst a helix tack is installed; this could lead to device damage or inadvertent detachment.Additional information: the device has not been returned for analysis.Dhr review was completed for lot number, af04884.The subject product met all specifications and requirements in effect at the time of manufacture.There was one other complaint in the apollo database against this lot number, af04884.Device evaluation summary: assessment of the device involved in this complaint was not possible, and it has not been possible to determine the root cause for this event.
 
Event or Problem Description
Premature of track not used.Inadequate anchoring of x-tack constructs.Ovesco 11/6t, 1 clip(competitors device) used in the case to close the perforation of the esophagus.Mucosal defect closure device.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
X-TACK¿ ENDOSCOPIC HELIX TACKING SYSTEM INSTRUCTIONS
Common Device Name
ENDOSCOPIC HELIX TACKING SYSTEM INSTRUCTIONS
Manufacturer (Section D)
APOLLO ENDOSURGERY, INC
1120 s. captail of texas hwy
bldg 1, ste 300
austin 78746
Manufacturer (Section G)
APOLLO ENDOSURGERY COSTA RICA, SRL
coyol free zone
building b 13.3
alajuela, cs CRI
CS   CRI
Manufacturer Contact
adriana russell
1120 s. captail of texas hwy
bldg 1, ste 300
austin 78746
5122795114
MDR Report Key18283636
Report Number3006722112-0230-00232
Device Sequence Number20500184
Product Code OCW
UDI-Device Identifier10811955020763
UDI-Public(01)10811955020763(17)20230125(11)20200125(10)AF04884
Combination Product (Y/N)N
Initial Reporter StateMN
Initial Reporter CountryUS
PMA/510(K) Number
K201808
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Study,Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 07/25/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date01/25/2023
Device Model NumberXTACK-160-H
Device Catalogue NumberXTACK-160-H
Device Lot NumberAF04884
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 07/25/2023
Initial Report FDA Received Date12/07/2023
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured01/25/2020
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient Age81 YR
Patient SexFemale
Patient Weight50 KG
-
-