MAUDE Adverse Event Report: ARROW INTERNATIONAL LLC ARROW HEMODIALYSIS SET: 2-LUMEN 14 FR X 15 CM; CATHETER, HEMODIALYSIS, NON-I

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ARROW INTERNATIONAL LLC ARROW HEMODIALYSIS SET: 2-LUMEN 14 FR X 15 CM; CATHETER, HEMODIALYSIS, NON-I Back to Search Results
Model Number IPN919946
Medical Device Problem Codes Disconnection (1171); Mechanical Problem (1384)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 11/14/2023
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
(b)(4).
 
Event or Problem Description
It was reported that: we had to connect a plasma exchange line to a patient with a right internal jugular dialysis catheter.The line was clamped and had caps at both ends.After removing the caps, we noticed that a clamp had opened.We immediately reclamped the clamp and aspirated the contents of the line.There was no trace of air, no air found.The doctor was immediately informed, no signs of distress were observed and the ultrasound performed by the medical team showed no abnormality.The device is still inserted in the patient at the time of logging.
 
Additional Manufacturer Narrative
(b)(4).The customer returned one, 2-lumen acute hemodialysis catheter for analysis.Signs of use in the form of biological material were observed on the catheter body.It was observed that the catheter body was severed.The severed end was not returned for analysis.It is being assumed that the customer intentionally severed the body during usage of the device.Visual analysis of the returned catheter did not reveal any defects or anomalies of any kind.The pinch clamps did not show any deformities and were correctly positioned on the extension lines.After performing functional testing, it was noted that both clamps were able to lock as intended.They appeared secure and successfully occluded both extension lines.Both pinch clamps were locked onto the respective extension line.No obvious issues were observed as both clamps were able to lock with little to no issue.After locking, the clamps felt secure and would not unlock when manipulating.Performed per ifu statement , "pinch clamp(s) are provided on extension lines to occlude flow through each lumen during line and luer-lock connector changes".A lab inventory syringe filled with water was then attached to both extension lines.With the pinch clamps activated, the lines were pressurized.The clamps appeared to fully occlude both extension lines.A device history record review was performed, and no relevant findings were identified.The ifu provided with the kit informs the user, "connect all extension line(s) to appropriate luer-lock connector(s) as required.Unused port(s) may be 'locked' through luer-lock connector(s) using standard institutional policies and procedures".The ifu also states, "open pinch clamp prior to infusion through lumen to reduce risk ofdamage to extension line from excessive pressure".The report that the pinch clamps do not lock was not able to be confirmed through complaint investigation.The returned clamps met all relevant visual and functional requirements, and a device history record review did not reveal any relevant findings.Based on the customer report and the sample received, no problem was found with the returned sample.Teleflex will continue to monitor and trend for reports of this nature.
 
Event or Problem Description
It was reported that: we had to connect a plasma exchange line to a patient with a right internal jugular dialysis catheter.The line was clamped and had caps at both ends.After removing the caps, we noticed that a clamp had opened.We immediately reclamped the clamp and aspirated the contents of the line.There was no trace of air, no air found.The doctor was immediately informed, no signs of distress were observed and the ultrasound performed by the medical team showed no abnormality.The device is still inserted in the patient at the time of logging.
 
Event or Problem Description
It was reported that: we had to connect a plasma exchange line to a patient with a right internal jugular dialysis catheter.The line was clamped and had caps at both ends.After removing the caps, we noticed that a clamp had opened.We immediately reclamped the clamp and aspirated the contents of the line.There was no trace of air, no air found.The doctor was immediately informed, no signs of distress were observed and the ultrasound performed by the medical team showed no abnormality.The device is still inserted in the patient at the time of logging.
 
Additional Manufacturer Narrative
Qn# (b)(4).Udi related data quality updates only.Section d.4 - udi # corrected to (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ARROW HEMODIALYSIS SET: 2-LUMEN 14 FR X 15 CM
Common Device Name
CATHETER, HEMODIALYSIS, NON-I
Manufacturer (Section D)
ARROW INTERNATIONAL LLC
morrisville NC
Manufacturer (Section G)
ARROW INTERNATIONAL CR, A.S.
jamska 2359/47
zdar nad sazavou 591 0 1
EZ   591 01
Manufacturer Contact
kevin don bosco
3015 carrington mill blvd
morrisville, NC 27560
MDR Report Key18299886
Report Number3006425876-2023-01219
Device Sequence Number7152196
Product Code MPB
UDI-Device Identifier10801902029215
UDI-Public(01)10801902029215(11)230227(17)270531(10)71F23B1442(21)
Combination Product (Y/N)N
Initial Reporter CountryFR
PMA/510(K) Number
K991431
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,User Facility,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial,Followup,Followup
Report Date (Section B) 11/14/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberIPN919946
Device Catalogue NumberCV-12142-UF
Device Lot Number71F23B1442
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer11/29/2023
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 11/14/2023
Supplement Date Received by Manufacturer01/03/2024
Not provided
Initial Report FDA Received Date12/11/2023
Supplement Report FDA Received Date01/04/2024
10/09/2024
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured02/27/2023
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
NOT REPORTED.; NOT REPORTED.; NOT REPORTED.
Patient SexUnknown
-
-