| Catalog Number |
0115320 |
| Medical Device Problem Codes |
Device Appears to Trigger Rejection (1524); Defective Device (2588); Patient Device Interaction Problem (4001)
|
| Health Effect - Clinical Codes |
Adhesion(s) (1695); Nerve Damage (1979); Pain (1994); Hernia (2240); Insufficient Information (4580)
|
| Date of Event |
10/11/2019
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
No conclusions can be made.The patient's attorney alleges adverse patient outcome associated with the hernia mesh used to treat the patient.The patient's attorney alleges that the patient had subsequent surgical intervention; however, no details have been provided.No lot number has been provided; therefore, a review of the manufacturing records is not possible.Should additional information be provided, a supplemental emdr will be submitted.Note: section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.H3 other text: not returned.
|
| |
|
Event or Problem Description
|
|
Attorney alleges that the patient underwent surgery for implant of an unspecified bard/davol 3dmax mesh on (b)(6) 2015.As reported, the patient is making a claim for an adverse patient outcome against the 3dmax mesh.Attorney alleges that the patient had subsequent surgical intervention due to the hernia mesh device.It is also alleged that the patient experienced emotional distress and the device was defective.
|
| |
|
Event or Problem Description
|
|
Attorney alleges that the patient underwent surgery for implant of an unspecified bard/davol 3dmax mesh on (b)(6) 2015.As reported, the patient is making a claim for an adverse patient outcome against the 3dmax mesh.Attorney alleges that the patient had subsequent surgical intervention due to the hernia mesh device.It is also alleged that the patient experienced emotional distress and the device was defective.Addendum per additional information provided: (b)(6) 2015 ¿ patient was diagnosed with bilateral inguinal hernia thereby underwent laparoscopic repair with implant of two 3dmax meshes (device 1 and 2).Per operative notes, ¿in right side, the indirect hernia with sac was dissected.A medium sized 3dmax mesh (device 1) was placed and tacked.In the left side, the indirect hernia sac was dissected and another 3dmax mesh (device 2) was placed around the cord structures sutured and tacked.¿ (b)(6) 2019 ¿ patient was diagnosed with recurrent right inguinal hernia and pain thereby underwent open repair with implant of bard flat mesh (device 3).Per operative notes, ¿an incarcerated recurrent inguinal hernia with mesh (device 1) protruding through indirect space and densely adhered to the ilioinguinal nerve was noted.The ilioinguinal nerve was dissected off and recurrent hernia was reduced and bard flat mesh (device 3) was placed and secured with sutures.¿.
|
| |
|
Additional Manufacturer Narrative
|
|
No conclusions can be made.The patient's attorney alleges adverse patient outcome associated with the hernia mesh used to treat the patient.The patient's attorney alleges that the patient had subsequent surgical intervention; however, no details have been provided.No lot number has been provided; therefore, a review of the manufacturing records is not possible.Addendum: this supplemental emdr is submitted to document additional information provided.Root cause is inconclusive; no conclusion can be made as to the extent to which the implant may have caused or contributed to the patient's postoperative course.Note, the manufacturing date (15-jun-2015) is considered to be a best estimate.Note: section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
|
| |
|