• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: SMITHS MEDICAL CZECH REPUBLIC A. S BLUPERC PERCUTANEOUS DILATION PROCEDURAL KIT WITH SINGLE STAGE DILATOR; TUBE TRACHEOSTOMY AND TUBE CUFF

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

SMITHS MEDICAL CZECH REPUBLIC A. S BLUPERC PERCUTANEOUS DILATION PROCEDURAL KIT WITH SINGLE STAGE DILATOR; TUBE TRACHEOSTOMY AND TUBE CUFF Back to Search Results
Catalog Number 101/561/080
Medical Device Problem Codes Obstruction of Flow (2423); Material Deformation (2976)
Health Effect - Clinical Codes Forced Expiratory Volume Decreased (2430); Low Oxygen Saturation (2477)
Date of Event 11/16/2023
Type of Reportable Event Serious Injury
Event or Problem Description
It was reported that there was no visible deformation of the cuff before the procedure.After insertion of the tracheostomy tube, oxygen saturation dropped.There was high ventilation pressure, no volume enters the patient.During re-bronchoscopy, the cannula opening was displaced by the cuff (cuff hernia).This lead to an immediate cannula change.After the cannula has been removed, there was lateral bulging of the cuff found.There was patient involvement, medical intervention required.Additional adverse effects to the patient have not been reported.
 
Additional Manufacturer Narrative
Investigation including root cause analysis is in progress.A supplemental mdr will be filed as necessary in accordance with 21 cfr 803.56 when additional reportable information becomes available.
 
Additional Manufacturer Narrative
Device evaluation: one device was received for investigation.During visual inspection no damage or anomalies were observed with the device.The reported issue was confirmed during functional testing, when the device cuff inflated unevenly.Although a definite root cause could not be established, the reported issue was attributed to over inflation of the cuff during use.The product's history records were reviewed and there were no non-conformances nor service-related issues that would have resulted in the reported complaint.As no manufacturing root cause could be identified, no further actions have been assigned.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BLUPERC PERCUTANEOUS DILATION PROCEDURAL KIT WITH SINGLE STAGE DILATOR
Common Device Name
TUBE TRACHEOSTOMY AND TUBE CUFF
Manufacturer (Section D)
SMITHS MEDICAL CZECH REPUBLIC A. S
olomoucka 306
hranice 753 0 1
EZ  753 01
Manufacturer Contact
reed covert
6000 nathan lane north
minneapolis, MN 55442
2247062300
MDR Report Key18335350
Report Number3011237704-2023-00002
Device Sequence Number8406525
Product Code BTO
UDI-Device Identifier15019517103373
UDI-Public(01)15019517103373(11)230807(17)260710(10)4399795
Combination Product (Y/N)N
Initial Reporter CountryGM
PMA/510(K) Number
K173912
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,User Facility
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 02/06/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date07/10/2026
Device Catalogue Number101/561/080
Device Lot Number4399795
Was Device Available for Evaluation? Yes
Date Returned to Manufacturer12/12/2023
Is the Reporter a Health Professional? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 11/20/2023
Supplement Date Received by Manufacturer01/08/2024
Initial Report FDA Received Date12/15/2023
Supplement Report FDA Received Date02/06/2024
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured08/07/2023
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient SexUnknown
-
-