MAUDE Adverse Event Report: ARTHREX, INC. SWIFTSTITCH HIP SUTURE PASSER; ORTHOPEDIC MANUAL SURG INSTR

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ARTHREX, INC. SWIFTSTITCH HIP SUTURE PASSER; ORTHOPEDIC MANUAL SURG INSTR Back to Search Results
Model Number SWIFTSTITCH HIP SUTURE PASSER
Medical Device Problem Code Device Dislodged or Dislocated (2923)
Health Effect - Clinical Codes Insufficient Information (4580); No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 11/17/2023
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The contribution of the device to the reported event could not be determined as the device was not returned for evaluation.The root cause of the event could not be determined from the information available and without device evaluation.If the device becomes available for evaluation, a follow-up report will be submitted.
 
Event or Problem Description
On 11/17/2023, it was reported by a sales representative via email that an ar-3636h self bunching 1.8 knotless hip fibertak pulled out of the bone.The knotless hip fibertak was initially inserted using the 20-degree curved drill guide and the new 1.8 flexible fluted drill ar-3600nd-2hf.The anchor was inserted, and the repair suture was passed through the labrum.The repair stitch was converted into the anchor and tensioned down to pull the labrum up.When tensioning the repair suture, the anchor pulled out of the bone.Additionally, when using an ar-4068hl swiftstitch suture passer shredded the repair sutures upon passing through.The swiftstitch suture passer was switched for another one, and the procedure was continued without further issues.This was discovered during a hip labral repair procedure on (b)(6) 2023.Additional information received on 11/22/2023: the case was completed using another ar-3636h self bunching 1.8 knotless hip fibertak.The patient had normal bone quality.
 
Additional Manufacturer Narrative
Additional information: g3, h3, h6.Based on the information provided, which may include the device (if available and returned), pictures, videos, event description, and any additional information from the field, arthrex was able to conclude a most likely cause.The most likely cause of the reported failure can be attributed to user error, specifically improper bone preparation.The complaint allegation was not confirmed.The device was not received for evaluation, and no evidence of the failure was provided.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SWIFTSTITCH HIP SUTURE PASSER
Common Device Name
ORTHOPEDIC MANUAL SURG INSTR
Manufacturer (Section D)
ARTHREX, INC.
1370 creekside boulevard
naples FL 34108 1945
Manufacturer (Section G)
ARTHREX, INC.
1370 creekside boulevard
naples FL 34108 1945
Manufacturer Contact
emily shafer
8009337001
MDR Report Key18340577
Report Number1220246-2023-09405
Device Sequence Number20518119
Product Code LXH
UDI-Device Identifier00888867300217
UDI-Public00888867300217
Combination Product (Y/N)N
Initial Reporter StateID
Initial Reporter CountryUS
PMA/510(K) Number
EXEMPT
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Distributor
Initial Reporter Occupation Administrator/Supervisor
Type of Report Initial,Followup
Report Date (Section B) 02/12/2025
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberSWIFTSTITCH HIP SUTURE PASSER
Device Catalogue NumberAR-4068HL
Device Lot Number3240134552
Was Device Available for Evaluation? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 11/17/2023
Supplement Date Received by Manufacturer01/20/2025
Initial Report FDA Received Date12/15/2023
Supplement Report FDA Received Date02/12/2025
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured09/01/2023
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-