Model Number M00539260
Medical Device Problem Codes Break (1069); Positioning Failure (1158); Stretched (1601); Use of Device Problem (1670); Detachment of Device or Device Component (2907); Material Deformation (2976)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 11/08/2023
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Block e1: (b)(6).Block h6: imdrf device code a0401 captures the reportable event of guide catheter break.
 
Event or Problem Description
It was reported to boston scientific corporation that a flexima biliary preloaded stent was to be implanted in the gallbladder for biliary drainage during an endoscopic retrograde cholangiopancreatography (ercp) performed on (b)(6) 2023.During the procedure, the stent could not be deployed, the guide catheter was broken, stretched, and kinked, and the suture was detached.A biopsy forceps was used to remove the broken pieces of the device.The procedure was completed with another flexima biliary preloaded stent.There were no patient complications reported as a result of this event, and the patients condition after the procedure was reported to be stable.Note: it was reported that the guidewire was inside the patient during the attempted deployment.However, the flexima biliary stent with delivery system instructions for use (ifu) states, "completely retract the guidewire into the endoscope.If the guidewire is not completely retracted into the delivery system, the stent cannot be fully deployed." the physician did not follow the steps cited in the ifu.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
FLEXIMA BILIARY
Common Device Name
CATHETER, BILIARY, DIAGNOSTIC
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
300 boston scientific way
marlborough MA 01752
Manufacturer (Section G)
BOSTON SCIENTIFIC CORPORATION
780 brookside drive
spencer IN 47460
Manufacturer Contact
carole morley
300 boston scientific way
marlborough, MA 01752
5086834015
MDR Report Key18372146
Report Number3005099803-2023-06795
Device Sequence Number7767128
Product Code FGE
UDI-Device Identifier08714729162575
UDI-Public08714729162575
Combination Product (Y/N)N
Initial Reporter CountryCH
PMA/510(K) Number
K965147
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Foreign,Health Professional,Company Representative,Distributor
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 12/21/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date03/23/2025
Device Model NumberM00539260
Device Catalogue Number3926
Device Lot Number0029105135
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 11/28/2023
Initial Report FDA Received Date12/21/2023
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured03/24/2022
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient Age57 YR
Patient SexFemale
Patient Weight100 KG
-
-