MAUDE Adverse Event Report: DATASCOPE CORP. - MAHWAH CS100 INTRA-AORTIC BALLOON PUMP, JAPANESE, 110V; SYSTEM, BALLOON, INTRA-AORTIC AND CONTROL

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

DATASCOPE CORP. - MAHWAH CS100 INTRA-AORTIC BALLOON PUMP, JAPANESE, 110V; SYSTEM, BALLOON, INTRA-AORTIC AND CONTROL Back to Search Results
Model Number 0998-00-3013-65
Medical Device Problem Code Output Problem (3005)
Health Effect - Clinical Codes Insufficient Information (4580); No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 12/19/2023
Type of Reportable Event Malfunction
Event or Problem Description
It was reported during patient use , the, cs100 intra-aortic balloon pump (iabp) displayed system malfunction , automatic filling error , message requiring inspection code #1.
 
Additional Manufacturer Narrative
A supplemental report will be submitted upon completion of our investigation.
 
Additional Manufacturer Narrative
Updated fields: b4, d9(device available for eval), g3, g6, h2, h3, h4, h6(investigation type, investigation findings & investigation conclusions), h10, h11.No response has been received from customer in regards to repair and status of iabp.If any information is received, the complaint will be reopened and updated accordingly and a follow up report will be submitted.H3 other text : evaluation not requested by complaintant.
 
Event or Problem Description
N/a.
 
Additional Manufacturer Narrative
Updated fields: b4, d9, g3, g6, h2, h3, h4, h6(type of investigation, investigation findings, component codes, investigation conclusion), h10 it was reported during patient use , the, cs100 intra-aortic balloon pump (iabp) displayed system malfunction , automatic filling error , message requiring inspection code #1.A getinge field service engineer (fse) evaluated the cs100 pump.Automatic filling error caused by leakage in the pneumatic circuit (solenoid valve).Fse replaced the drive manifold and confirmed that the symptoms had improved.Inspection, running.Test results were good.Patient involved.
 
Event or Problem Description
N/a.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CS100 INTRA-AORTIC BALLOON PUMP, JAPANESE, 110V
Common Device Name
SYSTEM, BALLOON, INTRA-AORTIC AND CONTROL
Manufacturer (Section D)
DATASCOPE CORP. - MAHWAH
1300 macarthur blvd
mahwah NJ
Manufacturer (Section G)
DATASCOPE CORP. - MAHWAH
1300 macarthur blvd
mahwah NJ
Manufacturer Contact
arelean guzman
1300 macarthur blvd
mahwah, NJ 
MDR Report Key18419264
Report Number2249723-2023-05561
Device Sequence Number17844512
Product Code DSP
UDI-Device Identifier10607567107684
UDI-Public10607567107684
Combination Product (Y/N)N
Initial Reporter CountryJA
PMA/510(K) Number
K112372
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Health Professional,User Facility,Company Representative
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup,Followup
Report Date (Section B) 05/29/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number0998-00-3013-65
Device Catalogue Number0998-00-3013-65
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 12/19/2023
Supplement Date Received by Manufacturer03/21/2024
05/29/2024
Initial Report FDA Received Date12/29/2023
Supplement Report FDA Received Date03/21/2024
05/29/2024
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured08/19/2005
Is the Device Labeled for Single Use? (Y/N) No
Usage of Device Reuse
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
UNKNOWN.
Patient SexPrefer Not To Disclose
-
-