| Catalog Number |
CMC1322P |
| Medical Device Problem Code |
Fracture (1260)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
12/06/2023
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
E1 phone number: (b)(6).Without a product return, no product evaluation is able to be conducted.Current information is insufficient to permit a valid conclusion about the cause of this event.If additional information is obtained that adds value to the relevant content of this report and/or a conclusion can be drawn, a follow-up report will be sent.
|
| |
|
Event or Problem Description
|
|
It was reported that the second plate of an roi-c construct could not be installed within the spacer intra-operatively.During installation of the second construct at the adjacent level, a piece of the anterior portion of the spacer broke off and was wedged in the channel between the spacer and the plate; the piece could not be recovered.There was a delay of 30 minutes to the procedure, but there have been no reported patient impacts.This is report two of two for this event.
|
| |
|
Additional Manufacturer Narrative
|
|
If additional information is obtained that adds value to the relevant content of this report, a follow-up report will be sent.Reference report (b)(4).
|
| |
|
Event or Problem Description
|
|
It was reported that the second plate of an roi-c construct could not be installed within the spacer intra-operatively.During installation of the second construct at the adjacent level, a piece of the anterior portion of the spacer broke off and was wedged in the channel between the spacer and the plate; the piece could not be recovered.There was a delay of 30 minutes to the procedure, but there have been no reported patient impacts.This is report two of two for this event.
|
| |
|
Event or Problem Description
|
|
It was reported that the second plate of an roi-c construct could not be installed within the spacer intra-operatively.During installation of the second construct at the adjacent level, a piece of the anterior portion of the spacer broke off and was wedged in the channel between the spacer and the plate; the piece could not be recovered.There was a delay of 30 minutes to the procedure, but there have been no reported patient impacts.This is report two of two for this event.
|
| |
|
Additional Manufacturer Narrative
|
|
H6: additional method code: 4109.Additional information in h6: component, investigation type, findings, and conclusions.Device evaluation: the product was not returned so an evaluation was unable to be performed, however photos were provided.The provided photos show that a inferior plate was not installed but do not clearly show that the cage was fractured so the complaint remains unrefuted.Root cause: a definitive root cause cannot be determined with the information provided.The second anchoring plate was unable to advance through the cage because the cage had fractured and a piece was jammed in the anchoring plate pathway.The cage fracture could be related to difficulty implanting the first anchoring plate.Dhr review: per dhr review, the part was likely conforming when it left zimvie control.Device usage: this device is used for treatment.If additional information is obtained that adds value to the relevant content of this report, a follow-up report will be sent.
|
| |
|