| Catalog Number |
8065751618 |
| Medical Device Problem Code |
No Flow (2991)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
11/07/2023
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
Investigation including root cause analysis is in progress.A supplemental mdr will be filed as necessary in accordance with 21 cfr 803.56 when additional reportable information becomes available.The manufacturer internal reference number is: (b)(4).
|
| |
|
Event or Problem Description
|
|
A nurse reported that no air flow in fluid and air exchange mode during vitrectomy surgery.The surgery was completed by replacing with another one.There was no patient harm.
|
| |
|
Additional Manufacturer Narrative
|
|
Additional information provided in d.9., h.3., h.6.And h.10.A review of the device history record traceable to the reported lot number indicates that the product was processed and released according to the product¿s acceptance criteria.Upon visual inspection of the returned cassette an identification (id) tab on the pinch plate was broken off.When the cassette was inserted onto a calibrated console the cassette was recognized as a posterior cassette with manual stopcock(incorrect) and passed priming and intraocular pressure (iop) calibration successfully.The ¿manual stopcock¿ output displayed by the console for the posterior cassette is incorrect for the cassette type and will result in fluid/air exchange (fax) detection issues the customer experienced.During fax mode, there was no exchange from liquid to air, liquid continued to flow to the infusion cannula.The customer's experience was replicated during laboratory testing.The investigation identified several potential factors that caused or contributed to this reported event.These include procedural gaps regarding post-inspection instructions, physical impact during storage and material movement of the pinch plate and/or cassette, and stress points due to limited surface area on the identification (id) tab.Action was taken to determine root cause and implement appropriate corrective action.To address root cause procedural enhancements were added to the visual inspection instructions for more control of non-conforming product and finite stress analysis will be performed that will aim on reducing the potential stress points on the id tabs.Quality assurance will continue to monitor customer complaints via the complaint review meetings and will take action for any future occurrences as is deemed necessary.The manufacturer internal reference number is: (b)(4).
|
| |
|
Additional Manufacturer Narrative
|
|
As per further review of the file, evaluation code was changed from d1101 to d03 the manufacturer internal reference number is: (b)(4).
|
| |
|