Model Number 1973-03
Medical Device Problem Code Entrapment of Device (1212)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 11/21/2023
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that the catheter was stuck on the guidewire.A 4.0 x 200mm, 150cm ranger drug-coated balloon was selected for use.The stenosed target lesion was located in the mildly tortuous and moderately calcified popliteal artery.During the procedure, when the physician tried to advance the ranger over the guide wire, it got stuck into the shaft.The device was removed from the patient and the procedure was completed with another of the same device.There were no patient complications.
 
Additional Manufacturer Narrative
Device evaluated by mfr: the complaint device was received for product analysis.The outer shaft, inner shaft, balloon and tip were visually and microscopically examined.Visual and microscopic examination revealed no damages.The device was tracked over a test 0.018" guidewire and it was able to pass through.Inspection of the remainder of the device presented no damage or irregularities.Product analysis could not confirm the reported froze on wire and found no damage that would have contributed to the reported event.
 
Event or Problem Description
It was reported that the catheter was stuck on the guidewire.A 4.0 x 200mm, 150cm ranger drug-coated balloon was selected for use.The stenosed target lesion was located in the mildly tortuous and moderately calcified popliteal artery.During the procedure, when the physician tried to advance the ranger over the guide wire, it got stuck into the shaft.The device was removed from the patient and the procedure was completed with another of the same device.There were no patient complications.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
RANGER PACLITAXEL-COATED PTA BALLOON CATHETER
Common Device Name
DRUG-ELUTING PERIPHERAL TRANSLUMINAL ANGIOPLASTY CATHETER
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
300 boston scientific way
marlborough MA 01752
Manufacturer (Section G)
HEMOTEQ AG
adenauerstrasse 15
wuerselen 52146
GM   52146
Manufacturer Contact
rachel shields
4100 hamline ave n
arden hills, MN 55112
6512422111
MDR Report Key18466495
Report Number2124215-2023-74752
Device Sequence Number3087384
Product Code ONU
UDI-Device Identifier08714729975885
UDI-Public08714729975885
Combination Product (Y/N)Y
PMA/510(K) Number
P190019
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Other,Foreign,Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 01/31/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date05/02/2025
Device Model Number1973-03
Device Catalogue Number1973-03
Device Lot Number03885H23
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer01/02/2024
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 12/19/2023
Supplement Date Received by Manufacturer01/12/2024
Initial Report FDA Received Date01/08/2024
Supplement Report FDA Received Date01/31/2024
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured05/03/2023
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient Age67 YR
Patient SexUnknown
Patient Weight73 KG
-
-