Catalog Number 186731740
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code Osteolysis (2377)
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.H10 additional narrative: d2b: additional product code: mni, mnh, kwp, kwq.D9: complainant part is not expected to be returned for manufacturer review/investigation.E3: reporter is a j&j sales representative.H3, h6: the investigation could not be completed; no conclusion could be drawn, as no product was received.Based on the information available, it has been determined that no corrective and/or preventative action is proposed.This complaint will be accounted for and monitored via post market surveillance activities.If additional information is made available, the investigation will be updated as applicable.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Event or Problem Description
Device report from synthes reports an event in japan as follows: it was reported that this was an unknown surgery on (b)(6) 2018.After the surgery, the extended re-fusion surgery will be performed due to the adjacent intervertebral disorders.It is confirmed l4/5 achieved osteosynthesis.The revision surgery was performed on (b)(6) 2023.The set screws, rods and the crosslinks were removed.Plif was performed on l1/2, and tlif was performed on l2/3 and extended.L1: expedium diameter5.0-40×2.L2 left: diameter5.0-45 right diameter6.0-45.L2/3: cageconcorde h8×w9×l23×angle5.Crosslink: a4 anda5.L1-l5: rod connection.Remarks: (b)(4) are involved with the same event.(b)(4) (depuy spine): screws.(b)(4) (synthes spine): cages.This report is for one (1) 5.5 ti cort fix 7x40mm.This is report 10 of 10 for complaint: (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
5.5 TI CORT FIX 7X40MM
Common Device Name
ORTHOSIS, SPINAL PEDICLE FIXATION, FOR DDD
Manufacturer (Section D)
MEDOS INTERNATIONAL SàRL CH
chemin-blanc 38
le locle 02400
SZ  02400
Manufacturer (Section G)
MEDOS INT SPINE
chemin blanc 38
le locle
SZ  
Manufacturer Contact
kate karberg
chemin-blanc 38
le locle 02400
SZ   02400
3035526892
MDR Report Key18476649
Report Number1526439-2024-00540
Device Sequence Number20435041
Product Code NKB
UDI-Device Identifier10705034352008
UDI-Public(01)10705034352008
Combination Product (Y/N)N
Initial Reporter CountryJA
PMA/510(K) Number
K160904
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2018
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Foreign,Health Professional,Company Representative
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Catalogue Number186731740
Device Lot Number202376
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 12/14/2023
Initial Report FDA Received Date01/09/2024
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Is the Device Labeled for Single Use? (Y/N) Yes
Usage of Device Unknown
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
5.5 TI CORT FIX 6X45MM.; 5.5 TI CORT FIX 6X45MM.; SINGLE-INNER SETSCREW.; SINGLE-INNER SETSCREW.; SINGLE-INNER SETSCREW.; SINGLE-INNER SETSCREW.; SINGLE-INNER SETSCREW.; SINGLE-INNER SETSCREW.; SINGLE-INNER SETSCREW.
Outcome Attributed to Adverse Event Required Intervention;
Patient SexUnknown
-
-