Catalog Number PXT231412
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code Aneurysm expansion (4597)
Date of Event 12/15/2023
Type of Reportable Event Serious Injury
Event or Problem Description
The following information was reported to gore:on (b)(6) 2012, this patient underwent an endovascular treatment using gore® excluder® aaa endoprosthesis for abdominal aortic aneurysm.On an unknown date, at follow-up examination, enlargement of the aneurysm diameter was confirmed.On (b)(6) 2023, the patient underwent reintervention.An additional stent graft was deployed to extend the right limb to the external iliac artery, and the internal iliac artery was embolized.Aneurysmorrhaphy was performed also.The cause of the aneurysm enlargement was not reported.
 
Additional Manufacturer Narrative
H.6.: code c19: a review of manufacturing records verified that the lot involved in this complaint met all pre-release specifications.H.6.: code b20: device remains implanted and therefore not available for direct analysis.H.6.: code d12: according to the gore® excluder® aaa endoprosthesis instructions for use (ifu), adverse events that may occur and / or require intervention or additional intraoperative procedure time include but are not limited to aneurysm enlargement.As gore was unable to determine which device/device component is involved in this reportable adverse event, the following additional devices will be identified in this report: ¿ device name: gore® excluder® aaa endoprosthesis ¿ lot # 20059739 ¿ catalog # pxc201400 ¿ udi # (b)(4).¿ device name: gore® excluder® aaa endoprosthesis ¿ lot # 20059739 ¿ catalog # pxc181000 ¿ udi # (b)(4).W.L.Gore & associates, inc.(gore) is submitting this report to comply with 21 c.F.R.Part 803, the medical device reporting regulation.This report is based upon information obtained by gore, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Blank fields present on this report include required fields and fields determined to be not applicable.Blank required fields indicate that the information was not provided, was deemed unavailable or was not applicable.This report does not constitute an admission or a conclusion by fda, gore, or its associates that the device, gore or its associates caused or contributed to the event described in the report.In particular, this report does not constitute a legal admission by anyone that the product described in this report has any defects or has malfunctioned, as defined from a legal standpoint.These words are included in the report and are fixed items for selection created by the fda, to categorize the type of event solely for the purpose of reporting pursuant to part 803.This statement should be included with any information or report disclosed to the public under the freedom of information act.
 
Additional Manufacturer Narrative
H.6.: investigation conclusions: d1001 added.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
GORE® EXCLUDER® AAA ENDOPROSTHESIS
Common Device Name
SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT
Manufacturer (Section D)
W. L. GORE & ASSOCIATES, INC.
1505 n. fourth street
flagstaff AZ 86004
Manufacturer (Section G)
MEDICAL WOODY MOUNTAIN B/P
3750 w. kiltie lane
flagstaff AZ 86005
Manufacturer Contact
kathryn irwin
1505 n. fourth street
flagstaff, AZ 86004
9285263030
MDR Report Key18504859
Report Number2017233-2024-04546
Device Sequence Number8145647
Product Code MIH
UDI-Device Identifier00733132610136
UDI-Public00733132610136
Combination Product (Y/N)N
Initial Reporter CountryJA
PMA/510(K) Number
P200030
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2012
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 02/23/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date03/31/2014
Device Catalogue NumberPXT231412
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 12/18/2023
Supplement Date Received by Manufacturer02/23/2024
Initial Report FDA Received Date01/12/2024
Supplement Report FDA Received Date02/23/2024
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured04/05/2011
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention; Other;
Patient Age86 YR
Patient SexFemale
-
-