| Model Number |
DDBB1D4 |
| Medical Device Problem Codes |
Pacing Problem (1439); Device Sensing Problem (2917)
|
| Health Effect - Clinical Code |
Bradycardia (1751)
|
| Date of Event |
10/13/2023
|
|
Type of Reportable Event
|
Malfunction
|
|
Event or Problem Description
|
|
It was reported that there was an episode with right atrial (ra) lead undersensing.It was further reported that the patient was brought into the clinic to assess atrial sensitivity and to determine if a ventricular fibrillation (vf) episode treated with anti-tachycardia pacing therapy was true vf or an atrial driven arrhythmia.In addition, the patient experienced bradycardia with heart rates below the programmed lower rate observed.The ra lead was reprogrammed but when the atrial sensing was changed there were no p waves at thirty bpm.The atrial sensitivity was also lowered but this resulted in far field r-wave (ffrw) oversensing, so the sensitivity was changed back to the previous setting.
|
| |
|
Additional Manufacturer Narrative
|
|
Medtronic is submitting this report to comply with fda reporting regulations under 21 cfr parts 4 and 803.This report is based upon information obtained by medtronic, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Medtronic has made reasonable efforts to obtain more complete information and has provided as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any ¿defects¿ or has ¿malfunctioned¿.These words are included in the fda 3500a form and are fixed items for selection created by the fda to categorize the type of event solely for the purpose of regulatory reporting.Medtronic objects to the use of these words and others like them because of the lack of definition and the connotations implied by these terms.This statement should be included with any information or report disclosed to the public under the freedom of information act.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
|
| |
|
Additional Manufacturer Narrative
|
|
Medtronic is submitting this report to comply with fda reporting regulations under 21 cfr parts 4 and 803.This report is based upon information obtained by medtronic, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Medtronic has made reasonable efforts to obtain more complete information and has provided as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any ¿defects¿ or has ¿malfunctioned¿.These words are included in the fda 3500a form and are fixed items for selection created by the fda to categorize the type of event solely for the purpose of regulatory reporting.Medtronic objects to the use of these words and others like them because of the lack of definition and the connotations implied by these terms.This statement should be included with any information or report disclosed to the public under the freedom of information act.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
|
| |
|
Event or Problem Description
|
|
It was reported that there was an episode with right atrial (ra) lead undersensing.It was further reported that the patient was brought into the clinic to assess atrial sensitivity and to determine if a ventricular fibrillation (vf) episode treated with anti-tachycardia pacing therapy was true vf or an atrial driven arrhythmia.In addition, the patient experienced bradycardia with heart rates below the programmed lower rate observed.The ra lead was reprogrammed but when the atrial sensing was changed there were no p waves at thirty bpm.The atrial sensitivity was also lowered but this resulted in far field r-wave (ffrw) oversensing, so the sensitivity was changed back to the previous setting.The ra lead and implantable cardioverter defibrillator (icd) remain in use.No further patient complications have been reported as a result of this event.
|
| |
|