• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: DENTSPLY LLC V3 RING UNIVERSAL (GREEN) 2 PACK; INSTRUMENTS, DENTAL HAND

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

DENTSPLY LLC V3 RING UNIVERSAL (GREEN) 2 PACK; INSTRUMENTS, DENTAL HAND Back to Search Results
Catalog Number 403342
Medical Device Problem Code Break (1069)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Type of Reportable Event Malfunction
Event or Problem Description
In this event it is reported that v3 ring universal (green) 2 pack broke during use.No injury.
 
Additional Manufacturer Narrative
While no serious injury resulted in this event, if this malfunction recurred, it could cause or contribute to a serious injury or require medical or surgical intervention to preclude such.This event, therefore, is reportable per 21cfr part 803.The device is available for evaluation, though has not been returned as of this report.Evaluation results will be submitted as they become available.
 
Additional Manufacturer Narrative
(b)(6) 2024: returned product 1 palodent v3 universal ring (green, v5 version) overmodling date codes ¿j¿ for october and ¿n¿ for 2022.This ring observed to have the overmolding tynes on one side broken and also noticed not symmetrical to the other side (images attached) and does not meet specification as per 0290-ip-7.5-60-58.There is no batch information provided in this case, therefore no dhr or retain evaluation can be conducted.Nc-2024-606 issued for this non-conformance.(nwv) failure mode: broken product root cause: manufacturing error conclusion code: product failure - manufacturing.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
V3 RING UNIVERSAL (GREEN) 2 PACK
Common Device Name
INSTRUMENTS, DENTAL HAND
Manufacturer (Section D)
DENTSPLY LLC
38 west clarke avenue
milford DE 19963
Manufacturer (Section G)
DENTSPLY LLC
38 west clarke avenue
milford DE 19963
Manufacturer Contact
hannah seevaratnam
221 west philadelphia st.
york, PA 17401
7178457511
MDR Report Key18542663
Report Number2515379-2024-00005
Device Sequence Number8903208
Product Code DZN
UDI-Device IdentifierD002659900V1
UDI-PublicD002659900V1
Combination Product (Y/N)N
Initial Reporter StateUT
Initial Reporter CountryUS
PMA/510(K) Number
EXEMPT
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional
Initial Reporter Occupation Dentist
Type of Report Initial,Followup
Report Date (Section B) 02/28/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Catalogue Number403342
Device Lot NumberUNKNOWN
Is the Reporter a Health Professional? Yes
Distributor Facility Aware Date01/18/2024
Type of Report(Section G)Follow-Up
Initial Date Received by Manufacturer 01/18/2024
Supplement Date Received by Manufacturer01/18/2024
Initial Report FDA Received Date01/19/2024
Supplement Report FDA Received Date02/28/2024
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Usage of Device A
Patient Sequence Number1
Patient SexUnknown
-
-