Catalog Number 1410MS
Medical Device Problem Codes Difficult to Remove (1528); Device Misassembled During Manufacturing /Shipping (2912); Material Twisted/Bent (2981)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 08/17/2023
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
H10: as the lot number for the device was provided, a review of the device history records is currently being performed.The device has been returned to the manufacturer for evaluation.The investigation of the reported event is currently underway.H10: d4: (expiration date: 06/2025).H11: section a: through f: the information provided by bd represents all the known information at this time.Despite good faith efforts to obtain additional information, the complainant reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
 
Event or Problem Description
It was reported that during an ultrasound guided breast biopsy procedure through hard density tissue, the needle was allegedly bent.It was further reported that the tissue collection failed, and tissue tear was allegedly felt.There was no reported patient injury.
 
Additional Manufacturer Narrative
H10: manufacturing review: the device history records have been reviewed and this lot met all release criteria.There was nothing found to indicate there was a manufacturing related cause for this event.Investigation summary: one mission disposable core biopsy instrument was received for evaluation.During visual evaluation, the device appeared to have residue throughout and the device was returned in primed configuration with the cannula at the 20mm position and the sample notch was not exposed.The device was engaged to reveal the sample notch.The sample notch was found to be bent backwards when positioned on a flat surface.No other visual anomalies were noted to the device.Further functional testing was not performed, due to the nature of complaint.Therefore, the investigation is confirmed for the reported bent needle issue as the sample notch was found to be bent.And the investigation is inconclusive for the reported difficult to remove issue as the condition of use cannot be replicated in the laboratory.And the investigation is inconclusive for the reported device misassembled during manufacturing /shipping issue as we do not have evidence of how the needle protector was placed on the device.A definitive root cause for the alleged bent needle, difficult to remove and device misassembled during manufacturing /shipping issues could not be determined based upon the provided information.Labeling review: as the reported event did not allege a labeling or use related issue, a labeling review is not required.H10: b5, d4 (expiration date: 06/2025), g3, h6 (device, method).H11: section a through f ¿ the information provided by bd represents all the known information at this time.Despite good faith efforts to obtain additional information, the complainant/reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
 
Event or Problem Description
It was reported that during an ultrasound guided breast biopsy procedure through hard density tissue, the needle was allegedly bent.It was further reported that the tissue collection failed, and tissue tear was allegedly felt.Reportedly, the needle guard protector was not in place upon opening the package.There was no reported patient injury.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
MISSION NEEDLE
Common Device Name
BIOPSY INSTRUMENT
Manufacturer (Section D)
BARD PERIPHERAL VASCULAR, INC.
1625 w 3rd st.
tempe 85281
Manufacturer (Section G)
CAREFUSION D.R. 203 LTD.
zona franca las americas
km 22-e-1
santo domingo 11606
DR   11606
Manufacturer Contact
brett curtice
800 w. rio salado pkwy
tempe, AZ 85281
4803032689
MDR Report Key18578089
Report Number2020394-2024-00114
Device Sequence Number8926055
Product Code KNW
UDI-Device Identifier00801741096945
UDI-Public(01)00801741096945
Combination Product (Y/N)N
Initial Reporter CountryKS
PMA/510(K) Number
K171953
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Other,Foreign,Health Professional,User Facility,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 02/02/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Catalogue Number1410MS
Device Lot Number0001475755
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer10/03/2023
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Follow-Up
Initial Date Received by Manufacturer 12/29/2023
Supplement Date Received by Manufacturer02/06/2024
Initial Report FDA Received Date01/25/2024
Supplement Report FDA Received Date02/07/2024
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured08/15/2022
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-