• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: COOK IRELAND LTD EVOLUTION® COLONIC CONTROLLED-RELEASE STENT - UNCOVERED; MQR STENT, COLONIC METALLIC EXPANDABLE

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

COOK IRELAND LTD EVOLUTION® COLONIC CONTROLLED-RELEASE STENT - UNCOVERED; MQR STENT, COLONIC METALLIC EXPANDABLE Back to Search Results
Catalog Number EVO-25-30-10-C
Medical Device Problem Code Material Twisted/Bent (2981)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 12/21/2023
Type of Reportable Event Malfunction
Event or Problem Description
User detected the stent cannot be released.User cannot confirm if the issue was caused by the sheath or stent.User has many years experience using the device, and it may not related to user's technique.Patient outcome: "a section of the device did not remain inside the patient¿s body.The patient did not require any additional procedures due to this occurrence.According to the initial reporter, the patient did not experience any adverse effects due to this occurrence.".
 
Additional Manufacturer Narrative
Pma/510(k) # k163468.Investigation is still pending, a follow up mdr will be submitted to include the investigation conclusions.
 
Additional Manufacturer Narrative
Pma/510(k) # k163468.Device evaluation the evo-25-30-10-c device of lot number c2057250 involved in this complaint was returned for evaluation, with its opened original packaging.With the information provided, a physical examination and document-based investigation was conducted.The device related to this occurrence underwent a laboratory evaluation on the 14th february 2024.On evaluation of the device, the following was observed: visual inspection: ¿ red safety tab not returned.¿ directional button in 'deployment' position.¿ safety/lock wire in place upon return.¿ red shuttle at 09th dimple (before point of no return).¿ kink noted directly below the handle.¿ outer catheter break noted approximately 28cm from white tip.Functional inspection: ¿ handle actuating fine for deployment and recapture.¿ unable to deploy stent due to outer catheter break.Kink at handle and flexor break were both observed by the customer prior to returning the device to cook manufacturing records review: prior to distribution all devices are subjected to a visual inspection and functional inspection to ensure device integrity.A review of the manufacturing records did not reveal any discrepancies that could have contributed to this complaint issue.Historical data review: the review of the relevant manufacturing records confirms the failure mode has not previously occurred for this work order.Instructions for use and/label review: it should be noted that the instructions for use (ifu0052) states the following: ¿if package is opened or damaged when received, do not use.Visually inspect with particular attention to kinks, bends and breaks.If an abnormality is detected that would prohibit proper working condition, do not use.Please notify cook for return authorization¿.There is no evidence to suggest that the customer did not follow the instructions for use or product label.Image review : an image was not returned for evaluation.Root cause analysis : a definitive root cause could not be determined as the circumstances of use cannot be replicated in the laboratory.A possible root cause could be attributed to handling of the device during the procedure or during device prep.The kink at the handle may have occurred if the handle was not adequately supported during use.The kink at the handle would have increased deployment force, causing the outer catheter to stretch and separate, subsequently leading to the issues reported.The kink at the handle and outer catheter break were observed in the lab evaluation.03 attempts were made to gain more information about this event, if more information becomes available, the file can be re-opened and updated.Confirmation of complaint: complaint is confirmed based on visual and/or functional inspection.Confirmed quantity of 01 x used device.Summary of investigation: according to the initial reporter, the patient did not experience any adverse effects due to this occurrence.Complaints of this nature will continue to be monitored for similar events.
 
Event or Problem Description
Supplemental report is being submitted due to the completion of the investigation on 26-jul-2024.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
EVOLUTION® COLONIC CONTROLLED-RELEASE STENT - UNCOVERED
Common Device Name
MQR STENT, COLONIC METALLIC EXPANDABLE
Manufacturer (Section D)
COOK IRELAND LTD
o halloran road
limerick
Manufacturer (Section G)
COOK IRELAND LTD
o halloran road
national technology park
limerick
Manufacturer Contact
sinead o'leary
o halloran road
national technology park
limerick 
MDR Report Key18607365
Report Number3001845648-2024-00036
Device Sequence Number9128051
Product Code MQR
UDI-Device Identifier10827002480381
UDI-Public(01)10827002480381(17)250529(10)C2057250
Combination Product (Y/N)N
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional,User Facility,Company Representative
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 07/26/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date05/29/2025
Device Catalogue NumberEVO-25-30-10-C
Device Lot NumberC2057250
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? No
Was the Report Sent to FDA? No
Distributor Facility Aware Date12/21/2023
Event Location Hospital
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 01/03/2024
Supplement Date Received by Manufacturer01/03/2024
Initial Report FDA Received Date01/30/2024
Supplement Report FDA Received Date08/09/2024
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured05/29/2023
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient Age71 YR
Patient SexMale
-
-