• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: DEROYAL INDUSTRIES, INC. CMC EXTREMITY PACK; GENERAL SURGERY TRAY (KIT)

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

DEROYAL INDUSTRIES, INC. CMC EXTREMITY PACK; GENERAL SURGERY TRAY (KIT) Back to Search Results
Model Number 89-10552
Medical Device Problem Code Contamination /Decontamination Problem (2895)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 09/11/2023
Type of Reportable Event Malfunction
Event or Problem Description
Pack was found to have a long dark colored hair in the inner wrapped blue basin.
 
Additional Manufacturer Narrative
A user facility medwatch report (#(b)(4)) was received on 1/23/2024 reporting pack was found to have a long dark colored hair in the inner wrapped blue basin.The sample was not returned for evaluation.The root cause for this event was unable to be determined by deroyal.There are these areas which could have contributed to hair being found within the procedure pack: possible employee failure to identify debris, possible dress code violation, lack of lab coat cleanliness, cleaning process not followed or inadequate, exposed product in warehouse, natural occurring static, and equipment has loose particulate.Per personnel dress code procedure corp.Prc.079, a mirror is placed in areas to allow employees to ensure that bouffant, beard covers and/or lab coats are applied appropriately.Personnel entering the clean manufacturing area shall perform the following steps prior to entering the room.Apply hair coverings, then next apply apparel, then if applicable apply shoe covers.Last step, wash or sanitize hands.Bouffant must cover all of hair.In order to contain all hair, more than one covering may be needed.Once a hair covering is removed, it must be discarded.Reapplication of the hair cover and beard/mustache cover must be with a new cover.Bouffant may not be worn outside of building.Brushing or combing of hair is not allowed in the changing room or any other area where products are handled or stored.Beard and/or mustache covers shall be worn in all areas that a bouffant hair covering is required and should cover all facial hair.Once removed, it must be discarded.Reapplication must be with a new cover.Lab coats are required in all clean manufacturing areas.Apparel / lab coats shall be buttoned/snapped.Apparel / lab coats shall be kept completely closed.Apparel / lab coats are not to be worn outside of the manufacturing area by manufacturing personnel.Per cleaning, sanitation and work environment procedure corp.Prc.086, machine operators shall ensure the work surface of each machine is free from dust, dirt, oil, debris and/or other foreign matter.All equipment used in production shall be cleaned.Garbage shall be removed daily as required by the respective cleaning checklist or form (do not transfer trash from one container to another).Daily - clean work area, work tables, manufacturing equipment, countertops and tables, empty trash, sweep floors and fatigue mats.The following corrective and or preventive actions have taken place by deroyal: this issue has been reviewed with the room supervisors due to no lot number was provided.The dress code procedure (corp.Prc.079) is posted at the door before entering the manufacturing area.Added additional guidance to the manufacturing instructions to indicate that these products have had reports of debris to increase scrutiny during the assembly process.An inventory check of the basin and basin wrap was made by deroyal, a total of 50 of the hd-395-6000-t and 5-10788 were inspected, and no discrepancies were identified during the inspection.This investigation is complete at this time.No further information is available at this time.We will provide follow-up report if additional information becomes available.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CMC EXTREMITY PACK
Common Device Name
GENERAL SURGERY TRAY (KIT)
Manufacturer (Section D)
DEROYAL INDUSTRIES, INC.
1501 east central avenue
lafollette TN 37766
Manufacturer (Section G)
DEROYAL INDUSTRIES, INC.
1501 east central avenue
lafollette TN 37766
Manufacturer Contact
melissa logsdon
200 debusk lane
powell, TN 37849
8653626157
MDR Report Key18614116
Report Number3005011024-2024-00003
Device Sequence Number20694173
Product Code LRO
UDI-Device Identifier00749756363549
UDI-Public00749756363549
Combination Product (Y/N)N
Initial Reporter StateVA
Initial Reporter CountryUS
PMA/510(K) Number
K842648
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date (Section B) 01/31/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Model Number89-10552
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 01/23/2024
Initial Report FDA Received Date01/31/2024
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-