Catalog Number 46100-91
Medical Device Problem Codes Crack (1135); Fluid/Blood Leak (1250)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 12/16/2023
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The device has been received for evaluation, however, investigation is not yet complete.
 
Event or Problem Description
The event involved a cath lab w/5 port "off" manifold (600 psi), 72" admin set and 4 ft transpac® iv where the customer reported that a set was leaking and connections were not secure.The customer further stated that the products were cracked, and fluid sprayed out the side of the connection to transducer when connected to pressure and fluid.There was patient involvement but no harm was reported as a consequence of this event.This is report one of two.
 
Additional Manufacturer Narrative
The reported complaint of a leak and connections would not secure was confirmed.During visual inspection, cracks and crazing near the cracks was observed on the female luer on both ends of the manifold.The returned set was primed and pressure leak tested and leaks were observed from the crack of the female luer on both ends of the manifold.The probable cause of the crack and crazing around the crack had occurred due to environmental stress cracking during use.The dhr for lot number 13672865 was reviewed and there were no relevant non-conformances found.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CATH LAB W/5 PORT "OFF" MANIFOLD (600 PSI), 72" ADMIN SET AND 4 FT TRANSPAC® IV
Common Device Name
CATHETER, INTRAVASCULAR, DIAGNOSTIC
Manufacturer (Section D)
ICU MEDICAL DE MEXICO, S. DE R.L. DE C.V.
avenida cuarzo no. 250
ensenada, b.cfa. 22790
MX  22790
Manufacturer Contact
reed covert
600 n. field dr.
lake forest, IL 60045
2247062300
MDR Report Key18632865
Report Number9617594-2024-00081
Device Sequence Number7889057
Product Code DQO
UDI-Device Identifier00840619070601
UDI-Public(01)00840619070601(17)260601(10)13672865
Combination Product (Y/N)N
Initial Reporter StateNC
Initial Reporter CountryUS
PMA/510(K) Number
K932141
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional,Company Representative
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 03/01/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date06/01/2026
Device Catalogue Number46100-91
Device Lot Number13672865
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer01/09/2024
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 01/04/2024
Supplement Date Received by Manufacturer02/01/2024
Initial Report FDA Received Date02/02/2024
Supplement Report FDA Received Date03/01/2024
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured06/01/2023
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-