ARTHROCARE CORPORATION REFLEX ULTRA 45 COBLATOR II; ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES Back to Search Results
Catalog Number EIC4845-01
Medical Device Problem Code Activation Failure (3270)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 09/11/2023
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that during a septoplasty, the front end of the reflex ultra 45 was not reacting when used.The procedure was completed with a s+n back up device.There was a surgical delay less than 30 minutes and no further complications were reported.Per the preliminary results of the investigation, the functional evaluation revealed intermittent power sparks were observed in the damaged tip assembly above the electrode.
 
Additional Manufacturer Narrative
H10: internal complaint reference (b)(4).H3, h6: the reported device was received for evaluation.A visual inspection revealed no manufacturing abnormalities.The electrode has been used and damaged.The tip assembly, that holds the electrode, has been damaged/crushed by another instrument.This finding has been determined to be related to the reported event.Product was out of the original packaging.No packaging returned.A functional evaluation was performed on the returned device and found the wand registered settings (4,2).Plasma was not generated at the electrode but intermittent power sparks were observed in the damaged tip assembly above it.A review of device records showed there were no indications to suggest that the product did not meet manufacturing specification upon release for distribution.A complaint history review found similar reported events.A risk management review found that the reported failure and/or harm was documented appropriately, and there were no indications to suggest the anticipated risk is not adequate the root cause has been associated with unintended use of the device.Factors that could have contributed to the failure include pressing the tip against rough or sharp surfaces or an impact event inconsistent with normal use, thus affecting the wand´s functionality.No containment or corrective actions are recommended at this time.
 
Additional Manufacturer Narrative
H2: additional information in g4 (510k).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
REFLEX ULTRA 45 COBLATOR II
Common Device Name
ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES
Manufacturer (Section D)
ARTHROCARE CORPORATION
7000 west william cannon drive
austin TX 78735
Manufacturer (Section G)
ARTHROCARE CORPORATION
7000 west william cannon drive
austin TX 78735
Manufacturer Contact
holly topping
7000 west william cannon drive
austin, TX 78735
5123913905
MDR Report Key18640847
Report Number3006524618-2024-00050
Device Sequence Number8042083
Product Code GEI
UDI-Device Identifier00817470004212
UDI-Public00817470004212
Combination Product (Y/N)N
Initial Reporter CountryCH
PMA/510(K) Number
K070374
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Other,Foreign,Health Professional,Company Representative
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 02/05/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date01/04/2026
Device Catalogue NumberEIC4845-01
Device Lot Number2110358
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer10/23/2023
Is the Reporter a Health Professional? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 02/05/2024
Supplement Date Received by Manufacturer02/05/2024
Initial Report FDA Received Date02/05/2024
Supplement Report FDA Received Date02/05/2024
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured01/04/2022
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-