| Catalog Number |
154635 |
| Medical Device Problem Codes |
Fracture (1260); Naturally Worn (2988)
|
| Health Effect - Clinical Code |
Failure of Implant (1924)
|
| Date of Event |
01/08/2024
|
|
Type of Reportable Event
|
Serious Injury
|
|
Event or Problem Description
|
|
It was reported that approximately twenty years after initial implantation, the patient underwent a revision surgery due to bearing fracture.Due diligence is in progress for this complaint; to date no additional information or product has been received.
|
| |
|
Additional Manufacturer Narrative
|
|
(b)(4).D10 - associated medical devices: unknown tibial component; item# unknown; lot# unknown.Unknown femoral component; item# unknown; lot# unknown.G2 - foreign: united kingdom.Investigation of this incident is currently ongoing.Once the investigation is completed, a supplemental medwatch 3500a will be submitted.
|
| |
|
Additional Manufacturer Narrative
|
|
Cmp-0916968 this follow-up report is being submitted to relay additional information.The following sections were updated: a1, a2, a3, a4, b4, b5, b7, d4, d9, d10, g3, g6, h2, h4, h6, h11.D10 - associated medical devices: oxford uni tib tray 53x34 rllm; item# 154615; lot# 683522; oxford uni femoral lg; item# 154602; lot# 639948.If any further information is found which would change or alter any conclusions or information, a supplemental report will be filed accordingly.Zimmer biomet will continue to monitor for trends.
|
| |
|
Event or Problem Description
|
|
It was reported that approximately twenty years after an initial left partial knee replacement, the patient was revised due to poly insert fracture at the medial posterior corner.During the revision, the surgeon also noted moderate wear of the poly.Poly was exchanged without complications.No further event information available at the time of this report.
|
| |
|
Additional Manufacturer Narrative
|
|
(b)(4).This follow-up report is being submitted to relay additional and/or corrected information.Assessment was conducted on the returned oxford bearing, which was in-vivo for approximately 20 years.The item was examined under magnification.While the bearing is fractured, no other fragments of the bearing were returned for examination.Both the superior and inferior surface of the bearing show evidence of multiple scratches, gouges, and/or abrasions.Additionally, the inferior surface shows some material missing from the medial posterior corner.There is also a significant indentation on the inferior side in the area of the missing material, with possible evidence of delamination or cracking.The anterior side of the bearing displays a worn area, which includes signs of possible creep or cold flow of uhmwpe material.Operative notes from the revision were provided and reviewed by a health care professional.The review identified the following: general anesthesia, previous incision utilized.Eua full rom, small effusion, no signs of infection.Poly insert medial posterior corner missing, small fragments retrieved, moderate wear.New poly stable, full rom.A review of the device manufacturing records confirmed no abnormalities or deviations.Review of the complaint history found no additional related complaints for this item.Based on the available information, a definitive root cause could not be determined.However, examination of the returned product indicates that the damage in the bearing surface was likely caused by overloading.This may have been influenced by a misalignment or movement of the bearing within the joint space, resulting in loading and articulation being shifted posteriorly.Further, the damage could have been exacerbated by embrittlement due to potential long-term oxidation of the uhmwpe.If any further information is found which would change or alter any conclusions or information, a supplemental report will be filed accordingly.Zimmer biomet will continue to monitor for trends.
|
| |
|
Event or Problem Description
|
|
No further event information available at the time of this report.
|
| |
|