Model Number 89-10578
Medical Device Problem Code Contamination /Decontamination Problem (2895)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 09/14/2023
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
A user facility medwatch report (b)(4) was received on 1/24/2024 reporting found large hair clump in pack.The actual sample was not returned for evaluation.However, a photo of the hair clump was provided.The root cause was determined that the assemblers failed to notice hair/debris on the back table cover.Per personnel dress code procedure corp.Prc.079, a mirror is placed in areas to allow employees to ensure that bouffant, beard covers and/or lab coats are applied appropriately.Personnel entering the clean manufacturing area shall perform the following steps prior to entering the room.Apply hair coverings, then next apply apparel, then if applicable apply shoe covers.Last step, wash or sanitize hands.Bouffant must cover all of hair.In order to contain all hair, more than one covering may be needed.Once a hair covering is removed, it must be discarded.Reapplication of the hair cover and beard/mustache cover must be with a new cover.Bouffant may not be worn outside of building.Brushing or combing of hair is not allowed in the changing room or any other area where products are handled or stored.Beard and/or mustache covers shall be worn in all areas that a bouffant hair covering is required and should cover all facial hair.Once removed, it must be discarded.Reapplication must be with a new cover.Lab coats are required in all clean manufacturing areas.Apparel / lab coats shall be buttoned/snapped.Apparel / lab coats shall be kept completely closed.Apparel / lab coats are not to be worn outside of the manufacturing area by manufacturing personnel.Per cleaning, sanitation and work environment procedure corp.Prc.086, machine operators shall ensure the work surface of each machine is free from dust, dirt, oil, debris and/or other foreign matter.All equipment used in production shall be cleaned.Garbage shall be removed daily as required by the respective cleaning checklist or form (do not transfer trash from one container to another).Daily - clean work area, work tables, manufacturing equipment, countertops and tables, empty trash, sweep floors and fatigue mats.The following corrective actions have taken place by deroyal: this issue has been reviewed with the room supervisors and the assemblers due to no lot number being provided.Added additional guidance to the manufacturing instructions to indicate that these products have had reports of debris to increase scrutiny during the assembly process.An inventory check of the back table cover was made by deroyal, a total of 20 of the 5-11976 were inspected, and no discrepancies were identified during the inspection.This investigation is complete at this time.No further information is available at this time.We will provide follow-up report if additional information becomes available.
 
Event or Problem Description
Found large hair clump in pack.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CMC VASCULAR ACCESS PACK
Common Device Name
GENERAL SURGERY TRAY (KIT)
Manufacturer (Section D)
DEROYAL INDUSTRIES, INC.
1501 east central avenue
lafollette TN 37766
Manufacturer (Section G)
DEROYAL INDUSTRIES, INC.
1501 east central avenue
lafollette TN 37766
Manufacturer Contact
melissa logsdon
200 debusk lane
powell, TN 37849
8653626157
MDR Report Key18659858
Report Number3005011024-2024-00004
Device Sequence Number8240618
Product Code LRO
UDI-Device Identifier00749756363495
UDI-Public00749756363495
Combination Product (Y/N)N
Initial Reporter StateVA
Initial Reporter CountryUS
PMA/510(K) Number
K842648
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source User Facility
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date (Section B) 02/07/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Model Number89-10578
Was Device Available for Evaluation? Yes
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 01/24/2024
Initial Report FDA Received Date02/07/2024
Was Device Evaluated by Manufacturer? (Y/N) No
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-