Model Number 7840
Medical Device Problem Codes Difficult to Advance (2920); Device Contamination with Chemical or Other Material (2944)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 01/19/2024
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that foreign material was present in the device.An expo diagnostic catheter was selected for use.During the procedure, the catheter was advanced in patient.However, an attempt to load the wire, the wire was not successful due to a white plastic piece being lodged in the catheter.The procedure was completed using an alternate device.No patient complications were reported.
 
Event or Problem Description
It was reported that foreign material was present in the device.An expo diagnostic catheter was selected for use.During the procedure, the catheter was advanced in patient.However, an attempt to load the wire, the wire was not successful due to a white plastic piece being lodged in the catheter.The procedure was completed using an alternate device.No patient complications were reported.
 
Additional Manufacturer Narrative
Device evaluated by mfr.: the device was returned for analysis.Visual and microscopic inspection found inner liner delamination.A photo provided by the customer depicted the catheter with the tip cut and the inner liner separated next to the tip.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
EXPO GUIDE CATHETER
Common Device Name
CATHETER, INTRAVASCULAR, DIAGNOSTIC
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
300 boston scientific way
marlborough MA 01752
Manufacturer (Section G)
FLEXTRONICS INTERNATIONL EUROPE B V
6201 america center drive
san jose CA 95002
Manufacturer Contact
rachel shields
4100 hamline ave n
arden hills, MN 55112
6512422111
MDR Report Key18667814
Report Number2124215-2024-07052
Device Sequence Number18225769
Product Code DQO
UDI-Device Identifier08714729187813
UDI-Public08714729187813
Combination Product (Y/N)N
Initial Reporter StatePA
Initial Reporter CountryUS
PMA/510(K) Number
K120495
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Health Professional,Company Representative
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 04/17/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date09/21/2025
Device Model Number7840
Device Catalogue Number7840
Device Lot Number0060497776
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer02/05/2024
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 01/19/2024
Supplement Date Received by Manufacturer03/28/2024
Initial Report FDA Received Date02/08/2024
Supplement Report FDA Received Date04/17/2024
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured09/21/2023
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-