EXACTECH, INC. LOGIC TIBIA PS MOD INSRT SZ 2 13MM; PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL
|
Back to Search Results |
|
| Catalog Number |
02-012-35-2013 |
| Medical Device Problem Codes |
Unstable (1667); Naturally Worn (2988)
|
| Health Effect - Clinical Codes |
Pain (1994); Synovitis (2094); Discomfort (2330); Osteolysis (2377); Joint Laxity (4526)
|
| Date of Event |
09/12/2023
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
H10.Pending investigation.There is no other information provided.
|
| |
|
Event or Problem Description
|
|
It was reported via legal documentation that a patient had a right total knee arthroplasty on 01-mar-2018, and then experienced a revision surgical procedure on (b)(6) 2023, approximately 5 years, 6 months after initial implant.There is no other information provided.
|
| |
|
Additional Manufacturer Narrative
|
|
Recall number: z-0021-2022.1038671-2024-04546.1038671-2024-04545.This follow-up report is being submitted to relay additional and/or corrected information.The product associated with the reported event is within the scope of recall z-0021-2022; however, there is insufficient information to evaluate whether the subject issue of the recall was a cause or contributor to the reported event.Multiple mdr reports were filed for this event, please see associated reports: 1038671-2024-04546, 1038671-2024-04545.The reason for the revision reported cannot be confirmed from the information provided but may be the result of prosthesis wear, instability, and femoral loosening or due to inclusion of the polyethylene in the packaging recall.Potential contributions of user and patient-related considerations to the event could not be assessed as the devices were not available for evaluation and images and radiographs were not provided.If any further information is obtained that would change or alter any information provided, a supplemental report will be filed accordingly.
|
| |
|
Event or Problem Description
|
|
It was reported via legal documentation that a patient had a right total knee arthroplasty, and then experienced a revision surgical procedure approximately 66 months after initial implant.Due to instability and prothesis wear, the patient was experiencing joint laxity, osteolysis, synovitis, discomfort, and pain.There is no other patient demographic or medical history available.There is no information on the surgical procedure or patient outcome.There is no device return.There are no photos or other images of the device provided.No additional information is available.
|
| |
|