• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: ABBOTT MEDICAL MITRACLIP G4 CLIP DELIVERY SYSTEM (MDD); MITRAL VALVE REPAIR DEVICES

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ABBOTT MEDICAL MITRACLIP G4 CLIP DELIVERY SYSTEM (MDD); MITRAL VALVE REPAIR DEVICES Back to Search Results
Catalog Number CDS0701-NTW
Medical Device Problem Code Incomplete Coaptation (2507)
Health Effect - Clinical Codes Mitral Valve Insufficiency/ Regurgitation (4451); Unspecified Tissue Injury (4559)
Date of Event 12/01/2023
Type of Reportable Event Serious Injury
Event or Problem Description
It was reported on (b)(6) 2022, a mitraclip procedure was performed to treat functional mitral regurgitation (mr) with a grade of 4.One ntw clip was implanted, reducing mr to a grade of 1-2.Roughly one year post procedure, the patient returned to the hospital.Echocardiography showed the implanted clip detached from the posterior leaflet and remained attached to the anterior leaflet (single leaflet device attachment/slda), causing mr to return to a grade of 4.It was noted a new posterior prolapse was observed.On (b)(6) 2024, an additional mitraclip procedure was performed.To stabilize the slda, two additional clips were implanted, reducing mr to a grade of 2.
 
Additional Manufacturer Narrative
The clip remains in the patient.The device will not be returned for evaluation.Investigation is not yet complete.A follow-up report will be submitted with all additional relevant information.B3: date of event estimated.
 
Additional Manufacturer Narrative
The device was not returned for analysis.A review of the lot history record identified no manufacturing nonconformities issued to the reported lot that would have contributed to the reported event.Additionally, a review of the complaint history identified no similar complaints from the lot.All available information was investigated and a cause for the reported slda cannot be determined.Mitral valve insufficiency/ regurgitation and tissue injury appear to be due to the slda.Mitral regurgitation and tissue damage are listed in the instructions for use (ifu) as known possible complications associated with mitraclip procedures.Unexpected medical intervention and hospitalization were a result of case-specific circumstances.There is no indication of a product issue with respect to manufacture, design or labeling.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
MITRACLIP G4 CLIP DELIVERY SYSTEM (MDD)
Common Device Name
MITRAL VALVE REPAIR DEVICES
Manufacturer (Section D)
ABBOTT MEDICAL
5050 nathan lane n
plymouth MN 55442
Manufacturer (Section G)
ABBOTT VASCULAR, REG # 3005070406
3885 bohannon drive
menlo park CA 94025
Manufacturer Contact
karen krouse
5050 nathan lane n
plymouth, MN 55442
6517565400
MDR Report Key18679902
Report Number2135147-2024-00597
Device Sequence Number7217392
Product Code NKM
UDI-Device Identifier08717648230967
UDI-Public08717648230967
Combination Product (Y/N)N
Initial Reporter CountryCA
PMA/510(K) Number
P100009
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2022
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 03/12/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date01/18/2023
Device Catalogue NumberCDS0701-NTW
Device Lot Number20118R182
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 01/18/2024
Supplement Date Received by Manufacturer02/26/2024
Initial Report FDA Received Date02/09/2024
Supplement Report FDA Received Date03/12/2024
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured01/19/2022
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention; Hospitalization;
Patient Age87 YR
Patient SexFemale
-
-