• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: BECTON DICKINSON MEDICAL SYSTEMS BD TWINPAK; SYRINGE 10ML LL W/TWINPAK DEVICE

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BECTON DICKINSON MEDICAL SYSTEMS BD TWINPAK; SYRINGE 10ML LL W/TWINPAK DEVICE Back to Search Results
Catalog Number 303393
Medical Device Problem Code Break (1069)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 01/19/2024
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
H.3.If a device evaluation and/or device history review is completed, a supplemental report will be filed.
 
Event or Problem Description
It was reported that the bd twinpak needles are defective.The following information was provided by the initial reporter: "we have been having a lot of trouble with our 10ml syringe item#303393 (ref#(b)(4)).I have attached pictures.The needle portion keeps breaking off, or is broken off.It appears to be the same lot (#3060712) that is having this issue.Just wondering if others are reporting this issue or if you know of a recall on this lot?".
 
Additional Manufacturer Narrative
Three samples and four photos of 10ml twin-pack syringes lot 3060712 were received and evaluated.Two of the samples were received in sealed packages and one in an unsealed package.All three samples have the needle broken at the red hub.Two of the photos show the top web portion of the web with one showing a close-up image of the batch #.The other two photos show the needle broken inside the sealed package, with one image showing all 3 samples, and the other a closeup image of the needle area.The condition observed is non-conforming per product specification.Potential root cause for the needle broken defect is associated with the assembly process.Most likely cause is the needle was over-torqued when applied to the syringe.A device history record review was completed for provided lot number 3060712 showing no rejected inspections or quality issues during the production of the provided lot number that could have contributed to the reported defect.
 
Event or Problem Description
Material#: 303393.Lot#: 3060712.It was reported by the customer that the needle portion keeps breaking off.Verbatim: rcc received a complaint via email.We have been having a lot of trouble with our 10ml syringe item#303393 (ref#303393.I have attached pictures.The needle portion keeps breaking off, or is broken off.It appears to be the same lot (#3060712) that is having this issue.Just wondering if others are reporting this issue or if you know of a recall on this lot?.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BD TWINPAK
Common Device Name
SYRINGE 10ML LL W/TWINPAK DEVICE
Manufacturer (Section D)
BECTON DICKINSON MEDICAL SYSTEMS
route 7 and grace way
canaan CT 06018
Manufacturer (Section G)
BECTON DICKINSON MEDICAL SYSTEMS
route 7 and grace way
canaan CT 06018
Manufacturer Contact
helen cox (mdr)
75 north fairway drive
vernon hills, IL 60061
8473935694
MDR Report Key18707367
Report Number1213809-2024-00082
Device Sequence Number8518200
Product Code FMI
UDI-Device Identifier30382903033936
UDI-Public(01)30382903033936
Combination Product (Y/N)N
Initial Reporter CountryCA
PMA/510(K) Number
K974006
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,User Facility
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 06/05/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Other
Device Catalogue Number303393
Device Lot Number3060712
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 01/19/2024
Supplement Date Received by Manufacturer06/05/2024
Initial Report FDA Received Date02/14/2024
Supplement Report FDA Received Date06/06/2024
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured03/01/2023
Is the Device Labeled for Single Use? (Y/N) Yes
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-