ABBOTT MEDICAL TRIFECTA¿ GT VALVE; HEART-VALVE, NON-ALLOGRAFT TISSUE Back to Search Results
Catalog Number TFGT-21A
Medical Device Problem Codes Material Split, Cut or Torn (4008); Intravalvular regurgitation (4068)
Health Effect - Clinical Codes Dyspnea (1816); Aortic Valve Insufficiency/ Regurgitation (4450)
Date of Event 01/03/2024
Type of Reportable Event Serious Injury
Event or Problem Description
It was reported that on (b)(6) 2017, a 21mm trifecta gt valve was successfully implanted.In (b)(6)2023, the patient visited a nearby facility due to difficulty breathing.On (b)(6) 2023, tear was observed in the stent area between the right coronary cusp and the non-coronary cusp.Severe aortic regurgitation was observed.On (b)(6) 2024, another procedure was performed.The trifecta was explanted and a 19mm valve was implanted.The patient is reported to be under rehabilitation.
 
Additional Manufacturer Narrative
Investigation is not yet complete.A follow-up report will be submitted with all additional relevant information.
 
Additional Manufacturer Narrative
Explant due to leaflet tear and severe aortic regurgitation was reported.The investigation found that leaflet 1 and leaflet 3 were torn.There was no acute inflammation or significant calcifications.The device history record was reviewed to ensure that each manufacturing and inspection operation was performed, and the product met all specifications.In the absence of any calcification or evidence for infection, the reported event is consistent with a non-calcific leaflet tear.A non-calcific leaflet tear is a form of structural valve deterioration (svd), which is a well-known complication from valve replacement surgery.A non-calcific leaflet tear is commonly attributed to increased operational leaflet stress but may also be related to biological factors which result in tissue degeneration characterized by loss of collagen.In this case, histological evaluation did not demonstrate loss of collagen at the tear site.The cause of the leaflet tear could not be conclusively determined.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
TRIFECTA¿ GT VALVE
Common Device Name
HEART-VALVE, NON-ALLOGRAFT TISSUE
Manufacturer (Section D)
ABBOTT MEDICAL
5050 nathan lane n
plymouth MN 55442
Manufacturer (Section G)
ST. JUDE MEDICAL #3014918977
edificio #44 calle 0, ave. 2
el coyol alajuela 1897- 4050
CS   1897-4050
Manufacturer Contact
karen krouse
5050 nathan lane n
plymouth, MN 55442
6517565400
MDR Report Key18711817
Report Number2135147-2024-00677
Device Sequence Number7186904
Product Code LWR
UDI-Device Identifier05415067018212
UDI-Public(01)05415067018212(17)181027(10)5730968
Combination Product (Y/N)N
Initial Reporter CountryJA
PMA/510(K) Number
P100029
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2017
Device Explanted Year2024
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 04/15/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date10/27/2018
Device Catalogue NumberTFGT-21A
Device Lot Number5730968
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer02/12/2024
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 01/22/2024
Supplement Date Received by Manufacturer04/12/2024
Initial Report FDA Received Date02/15/2024
Supplement Report FDA Received Date04/15/2024
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured10/27/2016
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Other; Required Intervention; Hospitalization;
Patient Age69 YR
Patient SexFemale
-
-