BD INFUSION THERAPY SYSTEMS INC. S.A. DE C.V. BD NEXIVA DIFFUSICS 20G X 1.00 IN; INTRAVASCULAR CATHETER Back to Search Results
Catalog Number 383592
Medical Device Problem Code Difficult or Delayed Separation (4044)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 01/23/2024
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that bd nexiva diffusics 20g x 1.00 in needle disengagement was difficult it was reported by the customer reported while starting iv on the patient with 20g diffusics, after inserting the needle in the vein, there was no flash back in the catheter or the attached pigtail, but blood started dripping from the joint where the white and the grey plastics meet.So advanced the catheter and pulled the needle out and a piece of metal fell from the grey piece.The needle did not come out attached to the grey piece.Showed the situation to a colleague.Then pulled the grey piece out manually and the iv flushed fine.Verbatim: hello bd team, good morning.On 01/23/2024, we had a safety event reported for bd item # 383592 (nexiva diffusics).Let¿s identify this as bd 262, as a reference number.The defective product is available for pick up from defect depot.Please contact ashlee shepard (copied here) with any questions you may have about pick up.Based on the information provided below, could you start a product quality report? bd 262: reported date: 01/23/2024; event date: 01/23/2024; item number: 383592; lot number: 3124280; item retained in defect depot?: yes; picture: yes, attached; patient harm: none; area: computerized tomography (ct) (roc) event details: ¿while starting iv on the patient with 20g diffusics, after inserting the needle in the vein, there was no flash back in the catheter or the attached pigtail but blood started dripping from the joint where the white and the grey plastics meet.So advanced the catheter and pulled the needle out and a piece of metal fell from the grey piece.The needle did not come out attached to the grey piece.Showed the situation to a colleague.Then pulled the grey piece out manually and the iv flushed fine.¿.
 
Additional Manufacturer Narrative
H.3.If a device evaluation and/or device history review is completed, a supplemental report will be filed.
 
Event or Problem Description
No additional information.
 
Additional Manufacturer Narrative
A device history record review was completed by our quality engineer team for provided material number 383592 and lot number 3124280.The review did not reveal any detected abnormalities during the production process that could have contributed to this defect and all quality tests were found to be within specification.As a sample was unavailable for return, a thorough sample investigation could not be completed.Based on the investigation results, an exact cause for this incident could not be identified.Should you again experience any problems with our product we would appreciate the opportunity to conduct a thorough analysis.There are quality controls currently in place to detect this type of defect during the production process.Further action has not been determined necessary at this time.Complaints received for this device and reported condition will continue to be tracked and trended.Our quality team regularly reviews the collected data for identification of emerging trends.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BD NEXIVA DIFFUSICS 20G X 1.00 IN
Common Device Name
INTRAVASCULAR CATHETER
Manufacturer (Section D)
BD INFUSION THERAPY SYSTEMS INC. S.A. DE C.V.
periferico luis donaldo
colosio no. 579
nogales
MX 
Manufacturer (Section G)
BD INFUSION THERAPY SYSTEMS INC. S.A. DE C.V.
periferico luis donaldo
colosio no. 579
nogales
MX  
Manufacturer Contact
helen cox (mdr)
75 north fairway drive
vernon hills, IL 60061
8473935694
MDR Report Key18722642
Report Number9610847-2024-00033
Device Sequence Number5740903
Product Code FOZ
UDI-Device Identifier30382903835929
UDI-Public(01)30382903835929
Combination Product (Y/N)N
Initial Reporter StateTX
Initial Reporter CountryUS
PMA/510(K) Number
K123734
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 03/28/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Other
Device Catalogue Number383592
Device Lot Number3124280
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 01/25/2024
Supplement Date Received by Manufacturer03/28/2024
Initial Report FDA Received Date02/16/2024
Supplement Report FDA Received Date03/29/2024
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Is the Device Labeled for Single Use? (Y/N) Yes
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-