STRYKER INSTRUMENTS-A DIVISION OF STRYKER CORP PERFORATOR CHUCK; DRILL, SURGICAL, ENT (ELECTRIC OR PNEUMATIC) INCLUDING HANDPIECE Back to Search Results
Catalog Number 5400210060
Medical Device Problem Codes Mechanical Jam (2983); Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 01/09/2024
Type of Reportable Event Serious Injury
Event or Problem Description
The user facility reported that the device stopped working during a procedure.A surgical delay of at least two hours was reported.The procedure was completed successfully with no medical intervention reported.This report is being submitted due to the prolongation of the surgical procedure.
 
Event or Problem Description
The user facility reported that the device stopped working during a procedure.A surgical delay of at least two hours was reported.The procedure was completed successfully with no medical intervention reported.This report is being submitted due to the prolongation of the surgical procedure.
 
Additional Manufacturer Narrative
D9, h3 h3 other text : device not returned, disposed of by user.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PERFORATOR CHUCK
Common Device Name
DRILL, SURGICAL, ENT (ELECTRIC OR PNEUMATIC) INCLUDING HANDPIECE
Manufacturer (Section D)
STRYKER INSTRUMENTS-A DIVISION OF STRYKER CORP
1941 stryker way
portage MI 49002
Manufacturer (Section G)
STRYKER INSTRUMENTS-KALAMAZOO
4100 east milham avenue
kalamazoo MI 49001
Manufacturer Contact
colette chung
1941 stryker way
portage, MI 49002
2693237700
MDR Report Key18735803
Report Number3015967359-2024-00403
Device Sequence Number12331153
Product Code HBB
UDI-Device Identifier04546540469229
UDI-Public04546540469229
Combination Product (Y/N)N
Initial Reporter CountryIR
PMA/510(K) Number
K041754
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source User Facility
Initial Reporter Occupation Biomedical Engineer
Type of Report Initial,Followup
Report Date (Section B) 04/24/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Catalogue Number5400210060
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 01/22/2024
Supplement Date Received by Manufacturer04/23/2024
Initial Report FDA Received Date02/19/2024
Supplement Report FDA Received Date04/24/2024
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured05/06/2019
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Reuse
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
Patient SexUnknown
-
-