MAUDE Adverse Event Report: ARROW INTERNATIONAL LLC ARROW HEMODIALYSIS SET: 2-LUMEN 12 FR X 20 CM; CATHETER PERCUTANEOUS

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ARROW INTERNATIONAL LLC ARROW HEMODIALYSIS SET: 2-LUMEN 12 FR X 20 CM; CATHETER PERCUTANEOUS Back to Search Results
Catalog Number CU-25122-F
Medical Device Problem Code Material Twisted/Bent (2981)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 01/29/2024
Type of Reportable Event Malfunction
Event or Problem Description
It was reported "the swg was found kinked during used on the patient".No medical intervention required.The patient condition is reported as "fine".
 
Additional Manufacturer Narrative
(b)(4).
 
Additional Manufacturer Narrative
Qn# (b)(4).The customer provided one image showing a guide wire assembly.The guide wire was observed to be kinked.It was also noted that the straightener tubing and cap were removed from the assembly and not pictured.The customer returned one guide wire assembly for analysis.The straightener tubing and cap were not included.Signs of use in the form of biological material were observed on the guide wire surface.Visual analysis revealed three kinks towards the distal end.This kinking resulted in the distal j-bend to be misshapen.Microscopic examination confirmed the damage and revealed that the distal and proximal welds were full and spherical.The kinks on the guide wire measured 655mm, 676mm, and 680mm from the proximal weld.The guide wire total length measured 685mm , which is within the specification limits of 678mm-688mm per the guide wire product drawing.The guide wire outer diameter measured 0.850mm, which is within the specification limits of 0.835mm-0.877mm per the guide wire product drawing.The returned guide wire was inserted through a lab inventory arrow raulerson syringe (ars)/introducer needle subassembly.Little to no resistance was encountered as the guide wire passed completely through the assembly.Performed per ifu statement , "advance guidewire into arrow raulerson syringe approximately 10 cm until it passes through syringe valves or into introducer needle".A manual tug test confirmed that the distal and proximal welds were secure and intact.A device history record review was performed, and no relevant findings were identified.The ifu provided with the kit informs the user, "do not apply excessive force in placing or removing catheter or guidewire.Excessive force can cause component damage or breakage.If damage is suspected or withdrawal cannot be easily accomplished , radiographic visualization should be obtained and further consultation requested." the report of a kinked guide wire was confirmed through complaint investigation.Visual analysis revealed that the guide wire was kinked on the distal j-bend.Despite the damage, the sample met all relevant dimensional and functional requirements, and a device history record review did not reveal any relevant findings.Based on the customer report and the sample received, unintentional use error likely caused or contributed to this event.Teleflex will continue to monitor and trend for reports of this nature.
 
Event or Problem Description
It was reported "the swg was found kinked during used on the patient".No medical intervention required.The patient condition is reported as "fine.".
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ARROW HEMODIALYSIS SET: 2-LUMEN 12 FR X 20 CM
Common Device Name
CATHETER PERCUTANEOUS
Manufacturer (Section D)
ARROW INTERNATIONAL LLC
morrisville NC
Manufacturer (Section G)
ARROW INTERNATIONAL CR, A.S.
jamska 2359/47
zdar nad sazavou 591 0 1
EZ   591 01
Manufacturer Contact
katharine tarpley
3015 carrington mill blvd
morrisville, NC 27560
MDR Report Key18737978
Report Number3006425876-2024-00133
Device Sequence Number6380095
Product Code DQY
UDI-Device Identifier00801902100276
UDI-Public00801902100276
Combination Product (Y/N)N
Initial Reporter CountryCH
PMA/510(K) Number
K862056
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,User Facility,Company Representative,Distributor
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 01/29/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Expiration Date01/30/2025
Device Catalogue NumberCU-25122-F
Device Lot Number71F23D0185
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 01/29/2024
Supplement Date Received by Manufacturer03/14/2024
Initial Report FDA Received Date02/20/2024
Supplement Report FDA Received Date03/15/2024
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured04/12/2023
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
NONE REPORTED; NONE REPORTED
Patient SexUnknown
-
-