Catalog Number ASCA5001-01
Medical Device Problem Codes Self-Activation or Keying (1557); Electrical Shorting (2926)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
H10: internal complaint reference number: (b)(4).H3, h6: the reported device was received for evaluation.Visual inspection observed the returned instrument showed no manufacturing abnormalities.The electrodes have been used.Bio debris is present.The device was sent out of the original packaging.No packaging returned.A functional evaluation showed that the device generated an e7 error when the wand was connected.When the bypass box was plugged in for use, the activate sound started and a light for the "coag" lit up, without being activated with the foot pedal, indicating a short.The resistance measured at 1.40 kilo ohms.A review of device records showed there were no indications to suggest that the product did not meet manufacturing specifications upon release for distribution.A complaint history review found no similar reported events.A risk management review found that the reported failure and/or harm was documented appropriately, and there were no indications to suggest the anticipated risk is not adequate.The root cause has been associated with an electrical component failure.Factors that could have contributed to the failure include moisture in the connection causing a wand short, incomplete connection or wire damaged inside the wand cable.No containment or corrective actions are recommended at this time.
 
Event or Problem Description
It was reported that, when the ambient megavac 90 was plugged to the bypass box for use, the activate sound started and a light for the "coag" lit up, without being activated with the foot pedal, indicating a short.The deficiency was observed while performing the investigation for the device; therefore, there was no patient involvement.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
AMBIENT MEGAVAC 90
Common Device Name
ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES
Manufacturer (Section D)
ARTHROCARE CORPORATION
7000 west william cannon drive
austin TX 78735
Manufacturer (Section G)
ARTHROCARE CORPORATION
7000 west william cannon drive
austin TX 78735
Manufacturer Contact
holly topping
7000 west william cannon drive
austin, TX 78735
5123913905
MDR Report Key18741898
Report Number3006524618-2024-00074
Device Sequence Number17704653
Product Code GEI
UDI-Device Identifier00817470001761
UDI-Public00817470001761
Combination Product (Y/N)N
Initial Reporter CountryGM
PMA/510(K) Number
K083306
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Other,Foreign,Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 02/20/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date06/08/2026
Device Catalogue NumberASCA5001-01
Device Lot Number2123340
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer02/16/2024
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 02/09/2024
Initial Report FDA Received Date02/20/2024
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured06/08/2023
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-