Model Number 83779
Medical Device Problem Codes Difficult to Remove (1528); Difficult to Advance (2920); Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 08/09/2023
Type of Reportable Event Malfunction
Event or Problem Description
Reportable based device analysis completed on 05feb2024.It was reported that advancing issue occurred.The target lesion was located in the iliac artery.A 12mm x 20cm interlock 2d coil was selected for use.During the procedure, the coil was advanced into the body through 18f microcatheter.However, resistance occurred in the tortuous lesion.The physician recaptured the coil and advanced again, but still could not push the device.The coil and catheter were removed together, and the procedure was completed with a new coil.No complications were reported, and the patient was stable.However, device analysis revealed main coil arm detachment.
 
Additional Manufacturer Narrative
E1 initial reporter facility name: (b)(6) hospital, (b)(6).Device evaluated by mfr.: the device was returned for analysis.Visual inspection was observed that the main coil, the introducer sheath and the pusher wire were returned.It was observed that the main coil was bent and stretched at the coil arm, zap tip and primary coil section.Also, the arm coil was detached.A part of the original box was returned, and it was observed that the pouch information matches with the complaint information.No more damages were observed.Functional inspection could not be performed due the main coil and the pusher wire are not interlocking.Dimensional inspection of the main coil zap tip outer diameter (od) and primary coil od pass the test.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
INTERLOCK
Common Device Name
DEVICE, VASCULAR, FOR PROMOTING EMBOLIZATION
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
300 boston scientific way
marlborough MA 01752
Manufacturer (Section G)
BOSTON SCIENTIFIC CORPORATION
model farm road
cork T12 Y K88
EI   T12 YK88
Manufacturer Contact
rachel shields
4100 hamline ave n
arden hills, MN 55112
6512422111
MDR Report Key18768624
Report Number2124215-2024-08213
Device Sequence Number15388377
Product Code KRD
UDI-Device Identifier08714729765042
UDI-Public08714729765042
Combination Product (Y/N)N
Initial Reporter CountryCH
PMA/510(K) Number
K132578
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Other,Foreign,Health Professional,Company Representative,Distributor
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 02/23/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date08/29/2025
Device Model Number83779
Device Catalogue Number83779
Device Lot Number0030244192
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer01/18/2024
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 02/05/2024
Initial Report FDA Received Date02/23/2024
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured09/29/2022
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient Age62 YR
Patient SexMale
Patient Weight85 KG
-
-