| Catalog Number |
14200100 |
| Medical Device Problem Codes |
Break (1069); Crack (1135); Fracture (1260); Failure to Align (2522)
|
| Health Effect - Clinical Codes |
Insufficient Information (4580); No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
01/31/2024
|
|
Type of Reportable Event
|
Malfunction
|
|
Event or Problem Description
|
|
It was reported that during use of the targeting arm the lag screw reamer missed the nail and broke.The surgeon was really wrenching on the arm trying to get the reamer to pass, which might have led to a crack in the targeter.According to additional information received the "surgeon opened 2nd reamer that continued to miss the nail - something was off the with the targeting arm.The surgeon hammered the reamer in, to proceed with the case.Surgeon was able to get the wider part of the reamer in.".
|
| |
|
Additional Manufacturer Narrative
|
|
Once the investigation has been completed any additional information will be reported in a supplemental report.
|
| |
|
Event or Problem Description
|
|
It was reported that during use of the targeting arm the lag screw reamer missed the nail and broke.The surgeon was really wrenching on the arm trying to get the reamer to pass, which might have led to a crack in the targeter.According to additional information received the "surgeon opened 2nd reamer that continued to miss the nail - something was off the with the targeting arm.The surgeon hammered the reamer in, to proceed with the case.Surgeon was able to get the wider part of the reamer in.".
|
| |
|
Additional Manufacturer Narrative
|
|
Please note that the device code grid (f10 / h6 medical device problem code) was corrected (from "crack" to "break" / "fracture").Lot code / d4 was corrected.The reported event could not be confirmed, since the device was returned in separated condition.No other evidence was provided.Thus, targeting accuracy could not be verified.A review of the inspection records for the reported lot did not indicate any abnormalities.No corrective actions are required at this time.A review of the labeling did not indicate any abnormalities.No indications of material, manufacturing or design related problems were found during the investigation.The device inspection revealed the following: the g4 prox.Targeting arm was returned in 2 pieces.The handle had broken at the 1st connection pin in the transition from upper component with metal part and lower component with drill holes.In the case presented it was alleged ¿¿ the lag screw reamer missed the nail and broke.The surgeon at that time was really wrenching on the arm trying to get the reamer to pass, so there could have been a crack made at that time.¿ functional check is required prior to surgery.If performed successfully, a targeting deficiency can only be caused by inadequate handling.Based on investigation, the root cause was attributed to a user related issue.With given information a product deficiency could not be verified.
|
| |
|