MAUDE Adverse Event Report: INTEGRA LIFESCIENCES MANSFIELD CRYOSOLUTIONS 4PK CARTRGE; M3

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

INTEGRA LIFESCIENCES MANSFIELD CRYOSOLUTIONS 4PK CARTRGE; M3 Back to Search Results
Catalog Number 33517
Medical Device Problem Code Leak/Splash (1354)
Health Effect - Clinical Code Caustic/Chemical Burns (2549)
Date of Event 01/24/2024
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
An investigation has been initiated based on the reported information.Upon completion of the investigation, a follow-up report will be submitted.E1: full name of reporting facility is (b)(6).
 
Event or Problem Description
This report is 1 of 2 for the cartridge used during this event and is linked to mfg number 3014334038-2024-00042.A facility reported that before a procedure, when the end user started screwing a cartridge of the cryosolutions 4pk cartridge (33517).Gas spilled out and froze the user's hands.The user experienced redness and tenderness to hands.Observation was performed.The cartridges were collected by the product distributor.
 
Additional Manufacturer Narrative
Updated fields: d4 (udi#).The suspected cryosolutions 4pk cartrge (33517) was not returned for evaluation and lot number information has not been provided; therefore, an evaluation of the device could not be performed, and manufacturing records could not be reviewed.As a result, a definitive root cause cannot be determined.The issue of gas exploding or spraying out may result from misalignment of the cartridge and control mechanism during setup.Instructions for use (ifu) directs user to "always use protective gloves when installing cartridges and using cryosolutions devices.The cartridge must be screwed into the control mechanism in a clockwise direction both quickly and completely.The pin must be fully inserted into the pin insertion point before attaching the cartridge.If additional relevant information becomes available in the future, this complaint will be reopened, and the respective evaluation performed.Trends will be monitored for this and similar issues.At present, we consider this complaint to be closed.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CRYOSOLUTIONS 4PK CARTRGE
Common Device Name
M3
Manufacturer (Section D)
INTEGRA LIFESCIENCES MANSFIELD
11 cabot boulevard
11 cabot boulevard
mansfield MA
Manufacturer (Section G)
INTEGRA LIFESCIENCES MANSFIELD
11 cabot boulevard
mansfield MA
Manufacturer Contact
vivian nelson
1100 campus drive
princeton, NJ 
6099362319
MDR Report Key18794052
Report Number3014334038-2024-00035
Device Sequence Number12595432
Product Code GEH
UDI-Device Identifier10381780171966
UDI-Public10381780171966
Combination Product (Y/N)N
PMA/510(K) Number
K091721
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source User Facility,Company Representative,Distributor
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 04/18/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Catalogue Number33517
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Type of Report(Section G)Initial
Initial Date Received by Manufacturer Not provided
Supplement Date Received by Manufacturer04/01/2024
Initial Report FDA Received Date02/27/2024
Supplement Report FDA Received Date04/18/2024
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Unknown
Patient Sequence Number1
Patient SexUnknown
-
-