• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: ORTHO-CLINICAL DIAGNOSTICS, INC. VITROS 350 CHEMISTRY SYSTEM; CHEMISTRY ANALYZER

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ORTHO-CLINICAL DIAGNOSTICS, INC. VITROS 350 CHEMISTRY SYSTEM; CHEMISTRY ANALYZER Back to Search Results
Catalog Number 6802153
Medical Device Problem Code Low Test Results (2458)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 02/05/2024
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The investigation determined that lower than expected sodium (na+) results were obtained from a non-vitros biorad quality control fluid using vitros chemistry products na+ slides lot 4218-1101-9669 on a vitros 350 chemistry system.The assignable cause of the lower than expected vitros na+ results is suboptimal calibrations.The tsc reviewed the parameters for the calibration events that were in use when the lower than expected vitros na+ result were obtained and determined them to be atypical when compared to the database values.The cause of the suboptimal calibrations is user error, as the customer programmed the vitros 350 system to calibrate the assays using an incorrect vitros cal kit lot.Following recalibration events of the assays on the instrument with the correct vitros cal kit lot programmed, post calibration qc results returned to expectation.
 
Event or Problem Description
A customer contacted the ortho clinical diagnostics (ortho) technical solution center (tsc) to report lower than expected sodium (na+) results were obtained from a non-vitros biorad quality control fluid using vitros chemistry products na+ slides lot 4218-1101-9669 on a vitros 350 chemistry system.Vitros na+ biorad lot 92960 level 2 results of 141, 141, 144, and 143 mmol/l versus the expected result of 156 mmol/l biased results of the magnitude and direction observed may lead to inappropriate physician action if they were to occur undetected on patient samples.The lower than expected vitros na+ results were obtained from a quality control fluid and no results were reported from the laboratory.There was no allegation of patient harm as a result of this event.This report corresponds to ortho clinical diagnostics inc (ortho) complaint number (b)(4) and reportability assessment (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
VITROS 350 CHEMISTRY SYSTEM
Common Device Name
CHEMISTRY ANALYZER
Manufacturer (Section D)
ORTHO-CLINICAL DIAGNOSTICS, INC.
100 indigo creek drive
rochester NY 14626
Manufacturer (Section G)
ORTHO-CLINICAL DIAGNOSTICS, INC.
100 indigo creek drive
rochester NY 14626
Manufacturer Contact
laurie o'riordan
1295 southwest 29th avenue
pompano beach, FL 33069
9549709500
MDR Report Key18828325
Report Number1319681-2024-00017
Device Sequence Number7878912
Product Code JJE
UDI-Device Identifier10758750002054
UDI-Public10758750002054
Combination Product (Y/N)N
Initial Reporter CountryUS
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Health Professional
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date (Section B) 02/28/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Catalogue Number6802153
Was Device Available for Evaluation? Yes
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 02/05/2024
Initial Report FDA Received Date03/04/2024
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured03/29/2013
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Patient SexUnknown
-
-