| Model Number |
N/A |
| Medical Device Problem Code |
Fracture (1260)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
(b)(4).The product has been received by zimmer biomet and the investigation is in process.Once the investigation has been completed, a follow-up mdr will be submitted.Multiple mdr reports were filed for this event, please see associated reports: 0001822565 - 2024 - 00745; 0001822565 - 2024 - 00747.
|
| |
|
Event or Problem Description
|
|
It was reported that the articular surface provisional was discovered fractured during instrument inspection at the distributorship office.No adverse events were reported as a result of this malfunction.
|
| |
|
Additional Manufacturer Narrative
|
|
This follow-up report is being submitted to relay additional information.Proposed component (annex g) code is mechanical (g04) - provisional top.Upon review of our reporting decision on fracture of articular surface provisionals.A review of all complaints for this product indicates that there has never been an event that has resulted in a death or serious injury.Therefore, zimmer biomet will not be reporting this failure mode going forward.Visual inspection of the returned item found it to exhibit signs of repeated use nicked / gouged and the medial feature has fractured off.All pieces were not returned.The device history records were reviewed for deviations and/ or anomalies with 1 anomaly/ deviation identified.Reported event did not occur in an operating room or as part of a medical procedure; medical records are not available for review.A definitive root cause cannot be determined.However, the summary of investigations for complaints associated with the tibial articular surface provisional (tasp) fracture were analyzed by optical microscopy revealing hackle marks and river lines in the case of bending overload; and hackle marks, river lines and striations were found in the case of low cycle fatigue culminating in a bending overload failure type.Complaint is confirmed via product review.If any further information is found which would change or alter any conclusions or information, a supplemental will be filed accordingly.Zimmer biomet will continue to monitor for trends.
|
| |
|
Event or Problem Description
|
|
No further event information is available at the time of this report.
|
| |
|
Search Alerts/Recalls
|