| Model Number |
DIB00 |
| Medical Device Problem Code |
Device Dislodged or Dislocated (2923)
|
| Health Effect - Clinical Codes |
Blurred Vision (2137); Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available (4581)
|
|
Type of Reportable Event
|
Serious Injury
|
|
Event or Problem Description
|
|
It was reported that the johnson and johnson (jnj) intraocular lens (iol) was explanted from the left eye.Reportedly, the patient¿s blurry vision may have been a miscalculation because the doctor had to change by two diopters.Doctor is not certain, but it seemed the iol was not positioned correctly, not sitting right in the eye.Customer said it could have been the patient¿s anatomy.The doctor is not saying the diopter is wrong, but he¿d like jnj to confirm it.The iol was replaced with another jnj model ar40e 23.0 diopter.The patient outcome is unknown.No further information was provided.
|
| |
|
Additional Manufacturer Narrative
|
|
Section a2, a4, a5 patient information: information unknown/not provided.Section b3, date of event: the exact date is unknown.The best estimate is between the implant and explant dates.(b)(6) 2023 and (b)(6) 2024, respectively.Section h3-other (81): the device has not been returned for evaluation.Therefore, a failure analysis of the complaint device cannot be completed.A review of the device history record, complaint trending, and risk documentation for this device will be performed.Upon completion of the review, if there is any further relevant information a supplemental medwatch will be filed.Section h6- health effect ¿ clinical code: 4581 used to capture device decentered or dislocated or tilted subluxated or wrong position: device dislocation.Attempts have been made to obtain the missing information.However, to date, it has not been received.All pertinent information available to johnson & johnson surgical vision, inc.Has been submitted.
|
| |
|
Additional Manufacturer Narrative
|
|
Additional information.Section d9: device available for evaluation? yes.Section d9: date returned to manufacturer: mar 25, 2024.Section h3: evaluated by manufacturer: yes.Device evaluation: the lens was visually inspected under magnification revealing that the lens was coated in viscoelastic residue.The lens was cleaned and inspected revealing that one haptic of the lens was detached, and the lens was damaged.No further issues were identified.Based on the complaint investigation results, the product was released within specifications.Conclusion: as a result of the investigation there is no indication of a product quality deficiency, and the reported issue could not be verified.All pertinent information available to johnson & johnson surgical vision, inc.Has been submitted.
|
| |
|
Search Alerts/Recalls
|