• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: CORDIS US CORP. AVANTI; DILATOR, VESSEL, FOR PERCUTANEOUS CATHETERIZATION

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

CORDIS US CORP. AVANTI; DILATOR, VESSEL, FOR PERCUTANEOUS CATHETERIZATION Back to Search Results
Catalog Number 504605X
Medical Device Problem Code Detachment of Device or Device Component (2907)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 02/09/2024
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Additional information is pending and will be submitted within 30 days upon receipt.
 
Event or Problem Description
As reported, the dilator of a 5f avanti plus sheath introducer with mini-guidewire broke when the doctor put it in the patient.The doctor tried again with a second 5f avanti sheath of the same lot and the same issue occurred.There was no reported patient injury.Femoral access was used.The intended procedure was not provided.It is unknown how the physician removed the dilator.Two (2) device pictures were received for review.Images attached to event show two dilators, which have been separated at the proximal end.There were no abnormalities noted on the product or product package.Additional event details were requested; however, not provided.The devices will not be returned for evaluation.
 
Additional Manufacturer Narrative
As reported, the dilator of a 5f avanti plus sheath introducer with mini-guidewire broke when the doctor put it in the patient.The doctor tried again with a second 5f avanti sheath of the same lot and the same issue occurred.There was no reported patient injury.Femoral access was used.The intended procedure was not provided.It is unknown how the physician removed the dilator.There were no abnormalities noted on the product or product package.Two pictures were submitted for analysis.The pictures included the device packaging, which included catalogue number 504-605x and lot number 18078557 on the packaging of two units.Additionally, both vessel dilators were observed separated near the hub.The reported ¿vessel dilator-separated¿ was confirmed for both devices by picture analysis however, the exact cause of the event cannot be determined without returning the device for analysis.Handling factors may have contributed to the reported event.Users are trained to inspect for signs of damage prior to and during use.Any product with damage is not to be used.Information for safety is provided in the products labeling with the intent to make the user aware of the risks.According to the instructions for use (ifu), although not intended as a mitigation of risk, ¿do not use if package is open or damaged.If increased resistance is felt upon insertion of the csi, investigate the cause before continuing.If the cause of the resistance cannot be determined and corrected, discontinue the procedure and withdraw the csi¿ based on the available information, there is no indication that the event is related to the device design or manufacturing process.Therefore, no preventive or corrective actions will be taken at this time.
 
Additional Manufacturer Narrative
After further review, section d.4 primary unique device identification (udi) number has been corrected accordingly.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
AVANTI
Common Device Name
DILATOR, VESSEL, FOR PERCUTANEOUS CATHETERIZATION
Manufacturer (Section D)
CORDIS US CORP.
14201 nw 60th avenue
miami lakes, florida 33014
Manufacturer (Section G)
CORDIS US CORP.
14201 nw 60th avenue
miami lakes, florida 33014
Manufacturer Contact
karla castro
santiago troncoso 808
juarez, chihuahua 
7863138372
MDR Report Key18849974
Report Number9616099-2024-00076
Device Sequence Number20716093
Product Code DRE
UDI-Device Identifier10705032009980
UDI-Public(01)10705032009980(17)251231(10)18078557
Combination Product (Y/N)N
Initial Reporter CountryUS
PMA/510(K) Number
K970392
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Foreign,Health Professional,Company Representative
Initial Reporter Occupation Other
Type of Report Initial,Followup,Followup
Report Date (Section B) 08/15/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date12/31/2025
Device Catalogue Number504605X
Device Lot Number18078557
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 02/12/2024
Supplement Date Received by Manufacturer04/01/2024
08/15/2024
Initial Report FDA Received Date03/06/2024
Supplement Report FDA Received Date04/11/2024
08/15/2024
Was Device Evaluated by Manufacturer? (Y/N) No
Date Device Manufactured01/15/2022
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-