• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: HOYA CORPORATION PENTAX TOKYO OFFICE PENTAX; STERILE DISTAL END CAP WITH ELEVATOR

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

HOYA CORPORATION PENTAX TOKYO OFFICE PENTAX; STERILE DISTAL END CAP WITH ELEVATOR Back to Search Results
Model Number OE-A63
Medical Device Problem Code Detachment of Device or Device Component (2907)
Health Effect - Clinical Code Device Embedded In Tissue or Plaque (3165)
Date of Event 01/01/2023
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
F10 continued: international medical device regulators forum (imdrf) adverse event reporting health effect clinical code: 3165 device embedded in tissue or plaque health effect impact code: 4604 delay to treatment/ therapy, 4641 unexpected medical intervention medical device problem code: 2907 detachment of device or device component component code: 424 cap.Customer did not record any of the lot numbers in any of the patient charts when this occurred.At this time they do not have traceability on the distal caps on which lot number was used.Per the account, they only have two lot numbers of sterile distal end cap model #: oe-a63 on site.Lot #: 0011112 & 0021122.D4: serial number is unknown.Pentax medical america performed good faith effort to gather additional information regarding this event and provided an email response on (b)(6) 2024 with the following information.Q1.Was the procedure for treatment or diagnostic purposes? a: treatment q2.Was there a delay in the procedure which would require medical intervention such as additional anesthesia or prolonged hospital stay? a: no.Q3.Was the product in question used to complete the procedure? a: no.Q4: if no, was a different or similar product used to complete the procedure? a: unknown.Q5.Please confirm if the fallen cap# oe-a63 was retrieved from the patient's body or not? a: it was.Q6.If retrieved, how did the doctor retrieve it? (using another medical device etc.) a:they had to stop the procedure, in order to retrieve the oe-a63 sterile distal end cap.Q7: did a nurse attach the cap# oe-a63 to the distal part of the endoscope? if so, did they hear the clicking sound when attaching it? a: doctor attached the oe-a63.Unknown at this time if he heard the click.Q8: how does the user consider the cause of the fallen cap# oe-a63? a: faulty equipment.Q9: does this facility have a pentax service contract? a:expired 1/31/2024 q10: was there a time prolongation of the procedure for retrieving the cap? no q11: did they receive the information and training about the proper use of cap# oe-a63? a: ifu s277-r01 was used for training and the hear the click training.Q12: was the patient recalled for further screening? a: no.Q13: if no, will the patient be recalled for further screening? a:unknown.Q14: what is the current status of the patient? a:unknown.Q15: was the product removed from circulation immediately after the failure/event occurred and subsequently called in for service/replacement? a: yes.Q16: device current location and status? a: customer site.Q17: is it possible to return the fallen retrieved cap? a: unknown q18: pre-procedural checks and use for the product involved? a: yes q19: reprocessing ifu? a: yes.Q20: any accessory involved ifu? a: n/a.Q21: reprocessing procedure: a: manual and automated.Investigation is in-process.If additional information becomes available, a supplemental report will be filed with the new information.Importer mdr 2518897-2024-00011, dec distal cap model oe-a63, lot number 0011112 or 0021122.Importer mdr 2518897-2024-00012, duodenoscope model ed34-i10t2 serial number unknown.
 
Event or Problem Description
Pentax medical was made aware of a complaint on (b)(6) 2024 that occurred during treatment in the united states involving a pentax medical sterile distal end cap(dec) model oe-a63, lot number 0011112 or 0021122.The sterile single use distal cap was used with pentax medical video duodenoscope, model ed34-i10t2, unknown serial number.The customer reported that during a procedure the oe-a63 sterile distal end cap fell off into the patient's stomach.They had to stop the procedure, in order to retrieve the oe-a63 sterile distal end cap.There was no reported harm to the patient and the patient was not recalled for further screening.B3: the exact date of occurence is unknown at this time, but customer stated it was approximately 6 months ago ((b)(6) 2023).Therefore, the b3 date of event was listed as 01-jan-2023.This event meets the requirements for fda reportability; however, submission of this report does not constitute an admission that medical personnel, user facility, importer, manufacturer or product caused or contributed to the event.
 
Additional Manufacturer Narrative
Correction information; b4: date of this report.B5.Refer to h11.F7: follow up #01.F11: updated dates.F13: updated dates.Additional information: d4: unique identifier (udi) corrected.H11: evaluation summary.Evaluation summary: the investigation determined that the distal end cap (dec) was not properly attached by the user and the endoscope most likely came into contact with the teeth or mouthpiece when it was taken out of the mouth, causing the dec to fall into the mouth due to the impact.Pentax medical has not received any further information for this event and therefore, considers this medwatch report closed.Importer mdr 2518897-2024-00011, dec distal cap model oe-a63, lot number 0011112 or 0021122 importer mdr 2518897-2024-00012, duodenoscope model ed34-i10t2 serial number (b)(6).
 
Event or Problem Description
Refer to h11.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PENTAX
Common Device Name
STERILE DISTAL END CAP WITH ELEVATOR
Manufacturer (Section D)
HOYA CORPORATION PENTAX TOKYO OFFICE
tsutsujigaoka 1-1-110
akishima-shi, tokyo 196-0 012
JA  196-0012
MDR Report Key18861777
Report Number2518897-2024-00011
Device Sequence Number20892841
Product Code FDT
UDI-Device Identifier04961333232994
UDI-Public04961333232994
Combination Product (Y/N)N
Initial Reporter StateTX
Initial Reporter CountryUS
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Importer
Initial Reporter Occupation Administrator/Supervisor
Type of Report Initial,Followup
Report Date (Section B) 05/20/2024
Report Date (Section F) 05/20/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Model NumberOE-A63
Device Lot Number0011112 OR 0021122
Was Device Available for Evaluation? No
Was the Report Sent to FDA? Yes
Distributor Facility Aware Date02/22/2024
Event Location Hospital
Date Report to Manufacturer05/20/2024
Type of Report(Section G)Follow-Up
Initial Date Received by Manufacturer Not provided
Supplement Date Received by ManufacturerNot provided
Initial Report FDA Received Date03/07/2024
Supplement Report FDA Received Date05/20/2024
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient SexUnknown
Date Report Sent to FDA05/20/2024
-
-