EXACTECH, INC. SMALL SUPERIOR AUGMENT GLENOID PLATE; SHOULDER PROSTHESIS, REVERSE CONFIGURATION
|
Back to Search Results |
|
| Model Number |
GLENOSPHERE, 36MM |
| Medical Device Problem Code |
Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Codes |
Bone Fracture(s) (1870); Periprosthetic fracture (4902)
|
| Date of Event |
02/12/2024
|
|
Type of Reportable Event
|
Serious Injury
|
|
Event or Problem Description
|
|
It was reported a female patient, initial left shoulder implanted on (b)(6) 2024, underwent a revision procedure on (b)(6), 2024.The patient fractured her glenoid.No fall or accident occurred.The surgeon removed the baseplate, hat, reconstructed the glenoid, and implanted a competitor¿s baseplate and exactech tray and liner to match.There were no surgical delays or device breakages during the procedure.The patient was last known to be in stable condition following the event.An x-ray was provided.The explanted devices are not available for analysis.The surgeon kept them.No further information.
|
| |
|
Additional Manufacturer Narrative
|
|
D10: concomitants: a699725 - 304-21-09 - 8.5mm platform fx stem left a496893 - 315-35-00 - glnd kwire 6898149 - 320-00-01 - 0 std left tray a791585 - 320-15-05 - eq rev locking screw a592211 - 320-20-00 - eq reverse torque defining screw kit s336580 - 320-20-22 - eq rev compress screw lck cap kit, 4.5 x 22mm s437460 - 320-20-22 - eq rev compress screw lck cap kit, 4.5 x 22mm s375722 - 320-20-30 - eq rev compress screw lck cap kit, 4.5 x 30mm a746504 - 320-35-02 - small superior augment glenoid plate a589552 - 320-36-00 - 145-deg pe 36mm hum liner +0 a826863 - 531-78-20 - shouldr gps hex pins kit additional information, including the product investigation, will be submitted within 30 days of receipt.
|
| |
|
Additional Manufacturer Narrative
|
|
This follow-up report is being submitted to relay additional and/or corrected information.The following sections were updated/corrected: d1, d4, h4, h6.Mdr section codes updated/corrected: b, c, d, e, g.The revision reported was likely due to a bone fracture.The reason for the fracture cannot be conclusively determined but may be related to implant positioning, patient bone quality, a trauma, and/or another patient related condition.However, this cannot be confirmed based on the information provided.If any further information is obtained that would change or alter any information provided, a supplemental report will be filed accordingly.
|
| |
|