| Model Number |
161006 |
| Medical Device Problem Code |
Gas/Air Leak (2946)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
02/22/2024
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
Hamilton medical ag case number is: cer (b)(4).
|
| |
|
Event or Problem Description
|
|
The following was reported to hamilton medical ag: release valve defective.No patient harm or consequences reported.Unknown if patient involvement.
|
| |
|
Additional Manufacturer Narrative
|
|
Hamilton medical ag case number is: (b)(4).Follow-up 1 - corrected information: a udi-di was provided for this device brand and version (generally) in the initial report, yet hamilton medical ag (hmag) established that this particular device (serial number: (b)(6)) was not labelled with a udi at the time of its manufacturing.Creation of udi was not a requirement at the time of manufacturing of this particular device (prior to 2015) and had not yet been implemented in production at hmag.Udi data has therefore been removed in this corrected follow-up report.A full udi (including udi-pi) will not be provided, this is in alignment with the information on the label on the device with the serial number (b)(6).Updated fields: b4, d1, d4, g6, h2, h4, h11.
|
| |
|
Event or Problem Description
|
|
The following was reported to hamilton medical ag: release valve defective.No patient harm or consequences reported.Unknown if patient involvement.
|
| |
|
Additional Manufacturer Narrative
|
|
Hamilton medical ag case number is: (b)(4).Follow-up 1 - corrected information: udi related data quality updates only an udi-di was provided for this device brand and version (generally) in the initial report, yet hamilton medical ag (hmag) established that this particular device (serial number: 3196) was not labelled with an udi at the time of its manufacturing.Creation of udi was not a requirement at the time of manufacturing of this particular device (prior to 2015) and had not yet been implemented in production at hmag.Udi data has therefore been removed in this corrected follow-up report.A full udi (including udi-pi) will not be provided; this is in alignment with the information on the label on the device with the serial number (b)(6).Updated fields: additional information added in follow-up #2 (b)(4).Field updated.Device alarms with (release valve defective) and tightness test failed.No patient involved.Consequently, the event did not cause or contributed to a death or serious injury.The tightness test is performed during startup of the ventilator to verify the integrity of the breathing circuit, ensuring there are no leaks that could compromise ventilation.The test is designed to detect leaks in the ventilator circuit, including tubing, connections, and the patient interface.It ensures that there is no unintended gas leakage that could affect ventilation performance.The operator's manual specifies that the preoperational check, which includes the tightness test, must always be conducted prior to patient use.Both the tightness test and the compensatory mechanisms for minor leaks are designed to ensure the ventilator operates safely and effectively.A failed tightness test or minor leak detection during ventilation does not indicate a malfunction but rather triggers the ventilator's safety mechanisms to either alert the operator or adapt to the situation.In conclusion, a failed tightness test is not a malfunction and should not be viewed as an immediate or critical failure.There is no information that reasonably suggest that the device has malfunctioned and that the device or a similar device would be likely to cause or contribute to a death or serious injury if the malfunction were to recur.Therefore, based on this information, the event is assessed as no longer reportable and the event can be closed with this follow up report.
|
| |
|
Event or Problem Description
|
|
The following was reported to hamilton medical ag: release valve defective no patient harm or consequences reported.Unknown if patient involvement.
|
| |
|
Search Alerts/Recalls
|