EXACTECH, INC. EQUINOXE REVERSE 46MM HUMERAL LINER +0; PROSTHESIS, SHOULDER, NON-CONSTRAINED, METAL/POLYMER CEMENTED
|
Back to Search Results |
|
| Catalog Number |
320-46-00 |
| Medical Device Problem Codes |
Detachment of Device or Device Component (2907); Device Dislodged or Dislocated (2923); Naturally Worn (2988)
|
| Health Effect - Clinical Codes |
Failure of Implant (1924); Joint Dislocation (2374); Joint Laxity (4526)
|
| Date of Event |
02/08/2024
|
|
Type of Reportable Event
|
Serious Injury
|
|
Event or Problem Description
|
|
As reported by the equinoxe shoulder study, the 58-year-old male patient had a right tsa on (b)(6) 2022.The patient presented with disassociation of polyethylene - patient has experienced chronic instability of the shoulder since pod2, then in one subluxation event, the polyethylene dissociated.The outcome of this event is considered resolved and the report indicates that the action taken is revision on (b)(6) 2024.The case report form indicates that this event is definitely related to the device and/or to the procedure.This event report was received through clinical data collection activities and no device return is anticipated.
|
| |
|
Additional Manufacturer Narrative
|
|
(d10) concomitant device(s): 300-30-06 - equinoxe preserve stem 6mm: (b)(6).320-10-00 - equinoxe reverse tray adapter plate tray +0: (b)(6).320-10-46 - glenosphere 46x21mm inset: (b)(6).320-15-04 - rs glenoid plate r post aug, 8 deg, right: (b)(6).320-15-05 - eq rev locking screw: (b)(6).320-20-00 - eq reverse torque defining screw kit: (b)(6).320-20-42 - eq rev compress screw lck cap kit, 4.5 x 42mm: (b)(6).320-20-42 - eq rev compress screw lck cap kit, 4.5 x 42mm: (b)(6).320-20-46 - eq rev compress screw lck cap kit, 4.5 x 46mm: (b)(6).(h3) pending evaluation.
|
| |
|
Additional Manufacturer Narrative
|
|
This follow-up report is being submitted to relay additional and/or corrected information.The revision reported cannot be confirmed from the information provided but may be the result of disassembly, prosthesis wear, dislocation, and/or instability.However, the reported disassembly, prosthesis wear, dislocation, and instability could not be confirmed.Potential contributions of user and patient-related considerations to the event, an unreported traumatic event, incomplete seating of the humeral liner during implantation, forceful contact between the liner and glenoid bone (scapular notching), or a combination of the above to the reported disassembly of the humeral liner cannot be determined as the devices were not available for evaluation and images, radiographs, and relevant clinical information were not provided.If any further information is obtained that would change or alter any information provided, a supplemental report will be filed accordingly.
|
| |
|